400 Hz converter maintenance and repairs, Tobyhanna, PA
You would perform preventive maintenance, diagnostic inspections and repairs on about 39 400 Hz cycle converters at Tobyhanna Army Depot, Pennsylvania, under a firm fixed price order.
Official title: 400 Hz Cycle Converters - Maintenance, Inspections, and Repairs
- Deadline
- Dec 14, 4:00 PM ET
- 19 days left
- Who can bid
- Small businesses
- Size standard for NAICS 811210: $34 million in average annual receipts · Who qualifies
- Last time
- $350K
- Likely Acr Technical Services Inc
- Place
- Tobyhanna, PA
- Buyer: W6QK ACC-APG Cont Ct Tyad Ofc
What they're buying
The base year runs from 06 Feb 2027 to 05 Feb 2028, with four option years ending 05 Feb 2032.
Top catches
“CMMC status at Level 2 (Self) or higher is required by the prime contractor at time of award.” W51AA1-27-Q-A004 Questions and Answers 2.xlsx
You must hold a current Cybersecurity Maturity Model Certification (CMMC) Level 2 (Self) status in the Supplier Performance Risk System (SPRS) before award. A subcontractor's status does not count, and Attachment III asks for your CMMC UID with the quote, so check your status now.
“referencing solicitation W51AA1-27-Q-A004 in the subject line of the email” Solicitation W51AA127QA004 Amendment 0001.pdf, page 6
Your quote goes by email only, and late or misrouted emails are not considered. Use the subject line W51AA1-27-Q-A004, which differs from the W51AA127QA004 number in box 5, send early and get written confirmation of receipt.
Read by AI (Claude Haiku) on Nov 25, 2026 from the notice and 7 of 9 attached files. Every quote on this page was found word for word in the source. Check the official notice before you bid.
The work
- Tier I units (14): quarterly preventive maintenance and inspections, priced as 4 lots per year.
- Tier II units (13): semi-annual preventive maintenance and inspections, priced as 2 lots per year.
- Tier III units (12): annual preventive maintenance and inspections, priced as 1 lot per year.
- Stage 1 call-outs: arrive on site within 48 hours, troubleshoot under load, and submit an itemized diagnostic report and repair quote within 15 days. Four call-outs per year are priced.
- Stage 2 repairs: start only after a bilateral modification funds them. Start within 5 business days, follow OEM specifications, and finish with a load test and completion report within 15 days.
Who did it before
$350K
on the contract that likely holds this work now: Acr Technical Services Inc. It ends May 20, 2027.
Matched in USAspending.gov by agency, NAICS and service code; notices rarely name the contractor.
What to watch for
- CMMC Level 2 status needed by award. You must hold a current Cybersecurity Maturity Model Certification (CMMC) Level 2 (Self) status in the Supplier Performance Risk System (SPRS) before award. A subcontractor's status does not count, and Attachment III asks for your CMMC UID with the quote, so check your status now.
- Email-only quote with exact subject. Your quote goes by email only, and late or misrouted emails are not considered. Use the subject line W51AA1-27-Q-A004, which differs from the W51AA127QA004 number in box 5, send early and get written confirmation of receipt.
- Emergency repairs unfunded until modification. Stage 2 repair work starts only after a later bilateral modification funds it, so you are not paid for it up front. Repair parts are billed at direct cost, and your Attachment III hourly labor rate is a binding maximum, so price it with care.“Any Stage 2 repair action must be proposed using your direct (at-cost) material expenses and a labor charge that does not exceed the hourly rate submitted in your Attachment III pricing worksheet.” W51AA1-27-Q-A004 Questions and Answers 2.xlsx
- Wage determination rates must be priced. A Service Contract Act wage determination (2015-5797, Revision 33) sets pay for these technicians, and its rates are not in the text provided. Get the full determination on SAM.gov and price the labor before you submit.“The labor category for lead field service technician is electronics mechanic (journeyman / senior) WG-2604-10 (or WL-10 leader)” W51AA1-27-Q-A004 Questions and Answers 2.xlsx
- Site visit access deadline has passed. Visitors without a depot-issued Contractor badge had to submit Form 648-C by November 23, 2026, and that date has passed. The site visit is recommended, not mandatory, so decide whether to attend and ask the Contracting Officer's Representative, Jay Reviello, what access is still possible.“than 12:00 p.m. on Monday, November 23, 2026.” RFQ W51AA127QA004 - 400Hz Coverters.pdf, page 3
- QASP cites a different CLIN and number. The Quality Assurance Surveillance Plan says emergency repairs fall under CLIN 0003, but the amendment and pricing worksheet use CLIN 0005. The plan also cites contract number W51AA1-26-Q-A057. Ask the contracting specialist to confirm the CLIN and number in writing before you price.“modification funding an FFP repair SLIN under CLIN 0003” Attachment II Quality Assurance Surveillance Plan.pdf, page 5
Key terms
| Who can bid | Small businesses only (100% small business set-aside)Size standard is $34.0 million average annual receipts for NAICS 811210. Your SAM registration must be active with no exclusions or delinquent federal debt.Notice text |
|---|---|
| Contract period | 06 Feb 2027 to 05 Feb 2028, plus four option yearsOption years run to 05 Feb 2032. A 6-month option to extend services is also included.RFQ W51AA127QA004 - 400Hz Coverters.pdf, page 16 |
| How they choose | Best value trade-off: price, technical and past performanceAward may not go to the lowest price. Key personnel items are scored acceptable or not acceptable.RFQ W51AA127QA004 - 400Hz Coverters.pdf, page 51 |
| How to submit | Email to Deborah Belak, Contract Specialist, at deborah.belak.civ@army.milThe subject line must reference W51AA1-27-Q-A004. The offer has three volumes: price, key personnel and technical, and Attachment III.Solicitation W51AA127QA004 Amendment 0001.pdf, page 6 |
| Questions due | No later than five calendar days before the RFQ response dateCounted from the 14 Dec 2026 closing, that is 9 Dec 2026. Questions go by email to Deborah Belak.RFQ W51AA127QA004 - 400Hz Coverters.pdf, page 3 |
| Contract type | Firm fixed price purchase orderLot-priced maintenance lines, with repair labor priced as an hourly rate on CLIN 0005.Notice text |
| Site visit | Monday, December 7, 2026, 10:00 a.m.Questions and Answers 2 say attendance is recommended, not mandatory. Meet at the Visitor Control Center, Scranton Gate.Notice text |
How to respond
- Confirm your SAM.gov registration, NAICS 811210 size status and CMMC Level 2 (Self) status in SPRS, and get your CMMC UID for the quote.
- Price Volume I: the SF 1449 blocks 30a to 30c, CLINs 0001 to 0005 and all option years, and the Attachment III pricing worksheet.
- Prepare Volume II: resumes for the contract manager, alternate and lead field technician, OSHA 30-hour certificates, and a capability summary of up to 3 pages.
- Email the complete quote to deborah.belak.civ@army.mil by 4:00 PM (-05:00) on Monday, December 14, 2026, with the subject line referencing W51AA1-27-Q-A004. Send early and confirm receipt.
- Keep your offer valid for at least 60 days from the closing date, and acknowledge all amendments in your offer.
Attached files
From SAM.gov. Download links open the original files.
- W51AA1-27-Q-A004 Questions and Answers 2.xlsxQuestions and answers from 24 November 2026 on CMMC timing, subcontractors, wage categories and Stage 2 pricing; read it, nothing to fill in. Read.
- W51AA1-27-Q-A004 Questions and Answers 1.xlsxQuestions and answers from 19 November 2026 that fix the unit count, tiers and emergency CLINs; read it, nothing to fill in. Read.
- https://sam.gov/api/prod/opps/v3/opportunities/resources/files/878c85af472e4f29aedde8d2858a0837/download Could not be read.
- Attachment II Quality Assurance Surveillance Plan.pdfHow the government will inspect your work and rate performance; read it, nothing to fill in. Read.
- Attachment III Proposed Pricing Worksheet.xlsxPricing worksheet you must complete with your company name, CAGE code, UEI, CMMC UID and a price for every CLIN; it is part of your proposal. Read.
- RFQ W51AA127QA004 - 400Hz Coverters.pdfThe main request for quote with the SF 1449 cover, instructions, clauses and CLIN list; you must complete the SF 1449 blocks 12, 17, 23, 24 and 30 and return it. Read.
- https://sam.gov/api/prod/opps/v3/opportunities/resources/files/aed789007dde4a07b0e843a8eff460f3/download Could not be read.
- Attachment IV 400 Hz Converters List.xlsxList of the converters with make, model, serial number and tier; read it to check the unit count, nothing to fill in. Read.
- Solicitation W51AA127QA004 Amendment 0001.pdfAmendment 0001 changes the email subject line, removes FAR 52.219-33 and corrects the CLIN reference in the PWS; you must acknowledge it with your offer. Read.
Not stated in what we read
- Two attachments on SAM.gov could not be read, so you must read them yourself before you bid.
- Estimated value or budget for the order is not stated.
- The Performance Work Statement (Attachment I) and Form 648-C (Attachment V) are named in the RFQ, but their text was not provided; you must read them on SAM.gov.
- Whether a subcontractor's OEM distribution channel can supply replacement parts is not answered.
- Insurance minimums under FAR 52.228-5 and any bonding requirement are not stated.
- Whether the two out-of-service units (#5 and #21) will be repaired and added to the scope is not stated.
Notice text
Request for Quote (RFQ) W51AA1-27-Q-A004 is being conducted in accordance with FAR Part 12, Acquisition of Commercial Products and Commercial Services and will utilize simplified procedures for soliciting competition, evaluation, award documentation and notification that complies with FAR Subpart 12.2. The Army Contracting Command (ACC) APG, Tobyhanna Division intends to award a firm fixed price (FFP) purchase order to provide preventative maintenance, diagnostic inspections, and repairs on approximately thirty-nine (39) 400 Hz cycle converters located at Tobyhanna Army Depot, Tobyhanna PA 18466, in accordance with Attachment I, Performance Work Statement.
In accordance with FAR Clause 52.237-1, a single site visit will be conducted at Tobyhanna Army Depot on Monday, December 7, 2026, at 10:00 a.m. This requirement is being solicited as a 100% small business set aside under NAICS 811210 (Electronic and Precision Equipment Repair and Maintenance) and PSC J059 (Maint/Repair /Rebuild of Equipment: Electrical and Electronic Equipment Components). The Small Business Administration (SBA) size standard for NAICS 811210 is $34.0 million (in average annual receipts).
As published on SAM.gov.
Contacts
- Deborah Belak, deborah.belak.civ@army.mil, 5706157579
As listed in the notice. Ask questions in writing and before the questions deadline, if the notice sets one.
Who may hold this work now
Contracts at Department of the Army for the same kind of work (NAICS 811210, service code J059) in Pennsylvania that end within a year either way of today. Notices rarely name the current contractor: these are likely candidates, not a fact.
| Contract | Obligated | Ends | State |
|---|---|---|---|
| Hass Ess Service ContractAcr Technical Services Inc · W51AA124P0063 | $350,177 | May 20, 2027in 5 months | PA |
Source: USAspending.gov, prime contracts of $100,000 or more. Department of Defense contracts appear there about 90 days after award.
History
- Nov 25, 2026: first seen in the SAM.gov extract
SAM.gov shows only the latest version of a notice. FedLook keeps a copy of each day's notices and records what changed.
Should you bid?
Dec 14, 4:00 PM ET19 days left
A free report for your company: whether you can bid, what to confirm first and who may hold the work now.
Get the free reportSimilar open notices
Open now under NAICS 811210, electronic and precision equipment repair and maintenance, soonest deadline first.
- Department of the NavyEvaluate and repair three CAMS units, Panama City Beach, FL
- Department of the Air ForceFlat panel up front controller repair, Warner Robins, GA
- Department of Veterans AffairsNeptune rover maintenance at Bay Pines and Cape Coral, FL
- National Institutes of HealthFlow cytometer service and repairs, Bethesda, MD
- Indian Health ServiceBody plethysmograph maintenance and repair, Lawton, OK
- Department of Veterans AffairsJ061 UPS and Battery Maintenance and Testing – Nashville VA Medical Center
- Department of Veterans AffairsNotice of Intent to Sole Source Rauland Nurse Call System Services
- National Institutes of HealthPreventive maintenance for two TracerLab units, Bethesda, MD
Free · at most one email a morning
Get new notices from Department of the Army by email
Each morning we'll send the new solicitations and sources-sought notices from Department of the Army, with deadlines and set-asides up front. Free. Unsubscribe in one click.
The morning edition by email: free, at most one email a morning, unsubscribe in one click. We use your address for nothing else and never share it. Privacy