1. Opportunities
  2. Department of Veterans Affairs
  3. 36C24527Q0073

Arc flash study and labels, VA hospital, Clarksburg, WV

The VA wants firms able to run a full arc flash hazard analysis and short circuit study of the Louis A. Johnson VA Medical Center electrical system in Clarksburg, WV, and to install arc flash warning labels on each analyzed piece of equipment.

Official title: Arc Flash Hazard Analysis Services

Deadline
Dec 1, 4:00 PM ET
6 days left
Who can respond
Any business
Market research, not a bid
Last time
None found
No contract like it at this agency in USAspending.gov
Place
Clarksburg, WV
Buyer: 245-Network Contract Office 5 (36C245)

What they're buying

This is market research only, so send a capability statement, not a price, by 4:00 PM (EDT) on December 1, 2026.

Top catches

Eastern time label conflicts
“Responses must be submitted by 4:00 PM (EDT) December 1, 2026.” 36C24527Q0073.pdf, page 2

The notice says 4:00 PM EDT, but the SAM record uses -05:00, which is Eastern Standard Time in December. Treat 4:00 PM Eastern Standard Time as the deadline and send your email well before then.

Not a bid; no pricing
“the U.S. Government is not seeking quotes, or proposals at this time and will not accept unsolicited quotes” 36C24527Q0073.pdf, page 2

This is market research. The government will not accept quotes or proposals, so send only a capability statement. Do not send a price, because nothing you send is paid for or returned.

4 more catches below ↓

Read by AI (Claude Haiku) on Nov 20, 2026 from the notice and 2 of 2 attached files. Every quote on this page was found word for word in the source. Check the official notice before you bid.

The work

  • Collect field data on the as-built electrical system, verify existing drawings, and photograph nameplates and overcurrent device settings for each equipment ID.
  • Build a computer model and one-line diagrams, then run a short circuit study including utility and generator operating modes.
  • Run an arc flash hazard analysis per IEEE 1584 and NFPA 70E, giving incident energy, boundaries, working distances, shock hazard limits and PPE for each location.
  • Furnish and install arc flash and shock hazard labels on every analyzed piece of equipment. Submit a sample label for approval before printing.
  • Deliver a work plan, draft and final reports, a label schedule, electronic model files, an equipment deficiency list, and a briefing for VA engineering staff.
  • Option periods: model and label updates, annual field verification of 15 percent of equipment, annual training, and a five-year review.

Who supplied it lately

No match in USAspending.gov: no contract at this agency for the same kind of work ends within a year either way.

What to watch for

  • Eastern time label conflicts. The notice says 4:00 PM EDT, but the SAM record uses -05:00, which is Eastern Standard Time in December. Treat 4:00 PM Eastern Standard Time as the deadline and send your email well before then.
  • Not a bid; no pricing. This is market research. The government will not accept quotes or proposals, so send only a capability statement. Do not send a price, because nothing you send is paid for or returned.
  • Licensed PE must seal study. The study must be done under a licensed professional engineer's direct supervision and sealed by that engineer. If you cannot provide a licensed engineer, you do not meet this requirement, so confirm that before you respond.“The study shall be performed under the direct supervision of, and sealed by, a licensed professional engineer.” Statement of Work-Arc Flash Hazard Analysis Services.pdf, page 2
  • NAICS code is a manufacturing code. The code given is for instrument manufacturing, but the work is engineering analysis and labeling. The notice does not state the size standard, so confirm it before you say you are small under this code.“NAICS: 334515 Instrument Manufacturing for Measuring and Testing Electricity and Electrical Signals” 36C24527Q0073.pdf, page 2
  • Work hours and outages limit schedule. Field work is set for Monday to Friday, 8am to 4:30pm. Outages must be requested in writing and approved in advance, and energized work needs written COR approval. Price for limited hours and possible approval delays.“Work shall be conducted within normal business hours Monday-Friday 8am-4:30pm.” Statement of Work-Arc Flash Hazard Analysis Services.pdf, page 4
  • Government data not guaranteed. The government furnishes drawings and prior studies but does not guarantee them. Plan for field verification and document discrepancies, and price that effort into your bid.“The government does not guarantee accuracy.” Statement of Work-Arc Flash Hazard Analysis Services.pdf, page 3

Key terms

Who can bidOpen; no set-aside usedThe notice asks whether you are small under NAICS 334515 and whether you hold a GSA schedule contract. The study must be sealed by a licensed professional engineer.SAM.gov record
Contract periodBase period plus four 12-month optionsThe base period length is not stated. The government may exercise each option at its sole discretion.Statement of Work-Arc Flash Hazard Analysis Services.pdf, page 8
How to submitEmail to veronica.dillard@va.govSend your capability information only. Do not send pricing.36C24527Q0073.pdf, page 2

How to respond

  1. Email your capability statement to veronica.dillard@va.gov by 4:00 PM (EDT) on December 1, 2026, treating it as Eastern Standard Time to be safe.
  2. Include your business name, address, business type, socio-economic status, contact name, telephone and email, and your UEI number.
  3. State whether your company is small under NAICS 334515, describe your past arc flash and short circuit experience, and say whether you hold a GSA Federal Supply Schedule contract and its number.
  4. Mark any sensitive or proprietary information clearly. Do not include pricing. File format, page limits and subject line: Not stated.

Attached files

From SAM.gov. Download links open the original files.

  • 36C24527Q0073.pdfThis is the sources sought notice. It lists the information to send by email and says no quotes are accepted. Read it. Nothing needs to be signed. Read.
  • Statement of Work-Arc Flash Hazard Analysis Services.pdfThis is the statement of work that describes the study, labels, deliverables and standards. Read it. Nothing needs to be filled in or signed for this response. Read.

Not stated in what we read

  • Estimated value or budget for the work.
  • Length of the base period and its start date.
  • Award basis and evaluation factors.
  • Whether a solicitation will follow, and when. The notice says any future RFQ is only if one is issued.
  • Final incident energy threshold. Sections 5.4 and 6 show [40] cal/cm² in brackets.
  • Referenced documents not attached, such as VA Master Specification Section 26 05 73 and the VA Electrical Design Manual.

Notice text

The Department of Veterans Affairs, Network Contracting Office 5 is conducting market research only to determine the availability of qualified Contractors capable of providing complete arc flash hazard analysis and short circuit study of the Louis A Johnson VA Medical Center’s (VAMC) electrical distribution system, and to furnish and install arc flash warning labels on all analyzed equipment.

As published on SAM.gov.

Contacts

As listed in the notice. Ask questions in writing and before the questions deadline, if the notice sets one.

History

  • Nov 20, 2026: first seen in the SAM.gov extract

SAM.gov shows only the latest version of a notice. FedLook keeps a copy of each day's notices and records what changed.

Free · at most one email a morning

Get new notices from Department of Veterans Affairs by email

Each morning we'll send the new solicitations and sources-sought notices from Department of Veterans Affairs, with deadlines and set-asides up front. Free. Unsubscribe in one click.

The morning edition by email: free, at most one email a morning, unsubscribe in one click. We use your address for nothing else and never share it. Privacy