- Opportunities
- Department of Health and Human Services
- National Institutes of Health
- 75N98027Q00038SB_PCA-NIA-11810
Replacement surgical light system, Baltimore, MD
The National Institute on Aging wants one Baxter/Hill-Rom Helux Pro surgical light system with a 4K camera, recording, a 55-inch monitor and a touchscreen controller, installed in its Baltimore clinical unit after the old unit is removed.
Official title: Baxter/Hill-Rom Helux Pro Surgical Light System
- Deadline
- Dec 8, 2:00 PM ET
- 12 days left
- Who can respond
- Any business
- Market research, not a bid
- Last time
- $232K
- Likely Iradimed Corporation
- Place
- Brooklyn, MD
- Buyer: National Institutes of Health OLAO
What they're buying
It is a small business set-aside on a firm fixed-price basis; contract length and budget are not stated.
Top catches
“Notice type: Sources Sought” SAM.gov record
The SAM.gov record says Sources Sought, but the document is a combined synopsis and solicitation asking for quotes under a set-aside. Treat it as a live solicitation with a firm deadline, and confirm the notice type with the contact.
“The purpose of this acquisition is to procure two wireless fiber photometry systems.” 75N98027Q00038SB.docx
The document also contains a purchase description for two wireless fiber photometry systems for a different lab. Ask the contact which description applies before you price anything.
Read by AI (Claude Haiku) on Nov 21, 2026 from the notice and 1 of 1 attached files. Every quote on this page was found word for word in the source. Check the official notice before you bid.
The work
- Remove and dispose of or return the existing ceiling-mounted surgical light without structural damage
- Supply and install one Helux Pro surgical lighthead with integrated 4K camera and single-arm ceiling mount
- Supply a 55-inch 4K DICOM wall monitor, 21-inch touchscreen controller, and rack-mounted video routing and dual-channel recording units
- Supply cabling including 50 m optic fiber HDMI, a standard cabling package, and wall mounts, with structural verification
- Price delivery to the 5th floor, trash removal, and a project management fee
- Provide a minimum 1-year OEM warranty and multi-year Protection+ service (3 years for the lighthead, 4 years for the integrated system)
Who supplied it lately
$232K
on a recent contract for the same kind of product: Iradimed Corporation. It ends Dec 2, 2026.
Matched in USAspending.gov by agency, NAICS and product code; notices rarely name the supplier.
What to watch for
- Notice type conflicts with document. The SAM.gov record says Sources Sought, but the document is a combined synopsis and solicitation asking for quotes under a set-aside. Treat it as a live solicitation with a firm deadline, and confirm the notice type with the contact.
- Second purchase description in file. The document also contains a purchase description for two wireless fiber photometry systems for a different lab. Ask the contact which description applies before you price anything.
- Brand named, equal not explained. The item is written as a named Baxter/Hill-Rom product, and the header says Brand Name or Equal, but no rule explains how an equal must be shown. Ask in writing whether an equal is accepted before you bid on a different product.“Baxter/Hill-Rom Helux Pro Surgical Light (replacement/upgrade)” 75N98027Q00038SB.docx
- Email-only submission at 2 PM. Quotes go by email only, to one address, and must be received by 2:00 PM Eastern on December 8. Send early, keep proof of sending, and confirm receipt with the contact.“Responses may be submitted electronically to johnsonjr@mail.nih.gov.” 75N98027Q00038SB.docx
- Delivery site differs in record. The SAM.gov record lists Brooklyn, MD, while the notice and delivery address say Baltimore at MedStar Harbor Hospital, 5th floor. Confirm the exact site and access rules before you price installation.“Place of performance: Brooklyn, MD, 21225, USA” SAM.gov record
- Size standard not given as number. The set-aside is for small businesses, but the notice gives no dollar size standard for NAICS 339112. Check your size under that code before you bid, and ask the contact if you are unsure.“The associated NAICS code is 339112, and the small business size standard is” 75N98027Q00038SB.docx
Key terms
| Who can bid | Small businesses only (total set-aside)The size standard is not given as a dollar or employee number.SAM.gov record |
|---|---|
| How they choose | Best value to the Government, price and other factors consideredFactors listed: price, technical capability, past performance, delivery schedule.75N98027Q00038SB.docx |
| How to submit | Email to johnsonjr@mail.nih.govReference solicitation number 75N98027Q00038SB/PCA-NIA-11810.75N98027Q00038SB.docx |
| Contract type | Firm fixed-priceCommercial item; not expected to exceed the simplified acquisition threshold.75N98027Q00038SB.docx |
How to respond
- Email your quote to johnsonjr@mail.nih.gov by Tuesday, December 8, 2026, 2:00 PM EST.
- Reference solicitation number 75N98027Q00038SB/PCA-NIA-11810 in your response.
- Include unit and total price, shipping and handling, delivery timeframe after award, delivery terms, F.O.B. point, product or catalog numbers, and product description.
- Include your UEI, your TIN, and a business size certification, and confirm you are actively registered in SAM.gov.
- Whether an equal product is accepted, and how it must be shown to meet the salient characteristics: Not stated.
Attached files
From SAM.gov. Download links open the original files.
- 75N98027Q00038SB.docxThe combined synopsis and solicitation for the surgical light, with a second, unrelated photometry purchase description. You must read it and return a priced quote that follows its submission list. Read.
Not stated in what we read
- Estimated value or budget for the contract
- Whether an equal to the Helux Pro is accepted and how it must be shown to comply
- Which purchase description applies: the surgical light or the wireless fiber photometry systems
- A firm delivery or installation date, since the text says as soon as possible
- The dollar size standard for NAICS 339112
- Whether questions are accepted and by what date
Notice text
The National Institute on Aging (NIA), Intramural Research Program (IRP), operates the Clinical Research Unit (CRU) located at the MedStar Harbor Hospital campus in Baltimore, Maryland. The CRU serves as the primary dedicated clinical facility supporting human longitudinal and translational aging research protocols, including the Baltimore Longitudinal Study of Aging (BLSA), the Genetic and Epigenetic Signatures of Translational Aging Laboratory Testing (GESTALT) study, and specialized clinical trials investigating age-related functional decline and metabolic disorders.
A cornerstone of these intramural clinical protocols involves invasive outpatient biopsy procedures—specifically percutaneous skeletal muscle biopsies, subcutaneous adipose tissue biopsies, and dermal skin punch biopsies. These procedures provide vital biospecimens for cellular, molecular, and physiological characterization of human aging. The existing ceiling-mounted surgical lighting system currently deployed in the CRU procedure suite has reached the end of its useful service life (End-of-Life / EOL).
The legacy unit is experiencing persistent operational failures. Critical replacement parts are no longer manufactured or supported by the original equipment manufacturer (OEM), rendering the existing unit non-serviceable. Because medical-grade illumination is a non-negotiable safety and operational prerequisite for procedural asepsis, precise anatomical depth perception, tissue differentiation, and hemostasis, the current state presents an unacceptable clinical risk and threatens immediate disruption to approved NIA protocol timelines.
As published on SAM.gov.
Contacts
- JOHNSON, JOHN R, johnsonjr@mail.nih.gov, 6673125580
As listed in the notice. Ask questions in writing and before the questions deadline, if the notice sets one.
Who has supplied this lately
Contracts at National Institutes of Health for the same kind of product (NAICS 339112, product code 6515) that end within a year either way of today. Notices rarely name the current supplier: these are likely candidates, not a fact.
| Contract | Obligated | Ends | State |
|---|---|---|---|
| Mri Infusion PumpsIradimed Corporation · 75N98026P01927 | $232,227 | Dec 2, 2026within a month | FL |
| Neuropace, Inc.:1336391 [26-001427]Neuropace Inc · 75N90026P00037 | $115,286 | Dec 29, 2026in 1 month | CA |
| Nhlbi: Supply: CD Leycom Inca Pressure Volume (PV) Loop Systems: N/aCardiodynamics B.V. · 75N98026P01100 | $242,357 | Oct 23, 2026ended | Not stated |
| Maxair Capr Systems and Components for Ongoing Operational Need to Support the Laboratories and Offices Across NIH to Sustain Mission Critical Activities for Public Health and Safety, and to Sustain…Bio-Medical Devices International, Inc. · 75N98026F00001 | $451,578 | Sep 30, 2026ended | CA |
| 25-006833 Stryker DefibrillatorsThe Janz Corp · 75N90025P00780 | $449,069 | Sep 30, 2026ended | OH |
Source: USAspending.gov, prime contracts of $100,000 or more. Department of Defense contracts appear there about 90 days after award.
History
- Nov 17, 2026: first seen in the SAM.gov extract
SAM.gov shows only the latest version of a notice. FedLook keeps a copy of each day's notices and records what changed.
Should you bid?
Dec 8, 2:00 PM ET12 days left
A free report for your company: whether you can bid, what to confirm first and who may hold the work now.
Get the free reportSimilar open notices
Open now under NAICS 339112, surgical and medical instrument manufacturing, soonest deadline first.
- Department of the ArmyAutomated external defibrillators for Army, Fort Drum
- Department of Veterans AffairsFY27 Cystos, Scopes and Resectoscope Trays
- National Institutes of HealthNotice of Intent to Sole Source – Siemens Medical Solutions USA Inc.
- Department of Veterans AffairsTunnel washer for VA animal facility, Decatur, GA
- Department of Veterans AffairsDefibrillator batteries and WiFi cards, Phoenix, AZ
- Defense Logistics AgencySix micro sample test kits for two AMC sites
- National Institutes of HealthUltrasound system for research, Bethesda, MD
- National Institutes of HealthDual-tuned 14 Tesla MRI coil, Baltimore, MD
Free · at most one email a morning
Get new notices from National Institutes of Health by email
Each morning we'll send the new solicitations and sources-sought notices from National Institutes of Health, with deadlines and set-asides up front. Free. Unsubscribe in one click.
The morning edition by email: free, at most one email a morning, unsubscribe in one click. We use your address for nothing else and never share it. Privacy