1. Opportunities
  2. Department of Veterans Affairs
  3. 36C24627B0001

Correct Electrical Deficiencies

Open, 22 days left

Deadline
Dec 8, 10:00 AM ET
Notice type
Solicitation
Set-aside
SDVOSB set-asideReserved for service-disabled veteran-owned small businesses (FAR 19.14).
Industry
Commercial and Institutional Building ConstructionNAICS 236220, Construction
Place of performance
Fayetteville, NC
Buying office
246-Network Contracting Office 6 (36C246)Office 36C246, Department of Veterans Affairs
Solicitation number
36C24627B0001
Product or service code
6150
Posted
Nov 5, 2026
Source
SAM.govVersion 1, last change seen Nov 16, 2026, 4:30 AM UTC

Notice text

SOW 565-22-500 Correct Electrical Deficiencies Fayetteville VAMC Intent The project consists of correcting electrical deficiencies as noted from previous VA facility assessments. Improvements include; New electrical entrance building, medium voltage loop replacement, replace electrical distribution equipment, ground conductor corrections, incidental electrical equipment cleanup throughout the Fayetteville VAMC, and minor HVAC and Plumbing improvements. Period of performance 1,174 calendar days. Medium Voltage VA owned medium voltage loop and entrance equipment will be modified or replaced with the following scope: Replace existing medium voltage entrance equipment with new at campus entrance. Provide new building: Slab on grade, brick on CMU wall, Slate roof tile (to match existing facility) Provide new VA owned medium voltage cables in concrete encased duct bank for medium voltage loop. Approximately 300 . Demo and remove old VA owned medium voltage entrance metal shack. Replace medium voltage sectionalized switch. Provide new metal-clad switchgear with draw-out vacuum circuit breakers. Replace medium voltage oil filled transformer (1) Panel Replacement and Branch Circuit Improvements Correct deficiencies to electrical panels and branch circuit wiring which are not correctly sized, protected, or are at end of useful life, as identified through various inspections over the years. o All work will be phased. All replacements to existing equipment will require the contractor to filled-out a phasing plan for VA approval. All replacements to existing equipment will require a temporary power solution to minimize electrical outage to existing areas. Such deficiencies include: Replace-in-same-room building entrance and large distribution equipment: Normal (service entrance) Switchboards: approx. 2 Generator switchboards: approx. 2 Automatic transfer switch: approx. 7 Replace-in-place distribution panels and panelboards distribution equipment Distribution Panels: approx. 5 Panelboards: approx. 68 Replace undersized feeders Redundant Gound Provide redundant equipment grounding conductor to a portion of the facility. Approx. 100,000 square feet of existing electrical branch circuit distribution in occupied space. HVAC And Plumbing Reroute (vertically & horizontally) Sewer piping and hot water piping to avoid electrical room. Provide exhaust fan to new Medium Voltage building. Incidental Electrical Equipment Cleanup Provide Identification tag to new and existing equipment throughout the facility: approx. 100 tags Clean debris from existing electrical enclosures throughout the facility: approx. 30 enclosures. Correct panel grounding, terminate cable directly to existing panel s ground bar: approx. 30 panels. ALTERNATE NO.1: BASE BID except delete Bldg 1, Floor 1 and Floor 3 of deficiency item 134 which directs the contractor to provide ground conductors in existing conduit. Which is noted on Sheet B01-E200.

As published on SAM.gov. Attachments are listed there; FedLook does not read them yet.

Contacts

As listed in the notice. Ask questions in writing and before the questions deadline, if the notice sets one.

History

  • Nov 16, 2026: first seen in the SAM.gov extract

SAM.gov shows only the latest version of a notice. FedLook keeps a copy of each day's notices and records what changed.

Other open notices in commercial and institutional building construction

NoticeSet-asidePlaceDue
ICD-705 Controlled Spaces Modernization and Sustainment Program - (Progressive Design-build (PDB) Other Transaction Agreement (OTA)Department of the Army, sources soughtNoneOsan Air Base, KORNov 17Due today
FY26 ZNRE224305P3 Improve Military Family Housing PAIP 9 Phase 3, Yokota Air Base, JapanDepartment of the ArmyNot statedNot statedNov 17Due today
DFC Bldg. 56 Clean Room - Design/BuildPublic Buildings ServiceNot statedLakewood, CONov 17Due tomorrow
Replace Chilled Water Pump at the Boiler PlantDepartment of Veterans AffairsSDVOSBBronx, NYNov 17Due tomorrow
Industry Day: Fort Hunter Liggett Barracks Pdb-OtaDepartment of the Army, special noticeNoneJolon, CANov 17Due tomorrow
Z ID-KOOSKIA NFH-Repair Electrical Service to MechanDepartmental OfficesSmall businessNot statedNov 17Due tomorrow
Design Build | NRM 654-27-130 | Eliminate Trip Hazards Facility Wide VASNHCSDepartment of Veterans Affairs, sources soughtNot statedReno, NVNov 17Due tomorrow
P084 Next Generation Torpedo Integration Lab, Naval Station Newport, Newport RiDepartment of the NavyNot statedNewport, RINov 17Due tomorrow

All open notices under NAICS 236220

Get new notices from Department of Veterans Affairs by email

Each morning we send the new solicitations and sources-sought notices from Department of Veterans Affairs, with deadlines and set-asides up front. Free. Unsubscribe in one click.