Fire system testing at Coast Guard base, Port Angeles, WA

Annual inspection, testing, and maintenance of fire protection systems in several buildings at Coast Guard Air Station Port Angeles, including an aircraft hangar.

Official title: U.S. Coast Guard Air Station Port Angeles Annual Fire Suppression & System Tests

Deadline
Dec 11, 3:00 PM PT
16 days left
Who can bid
Small businesses
Size standard for NAICS 541990: $19.5 million in average annual receipts · Who qualifies
Last time
None found
No contract like it at this agency in USAspending.gov
Place
Port Angeles, WA
Buyer: Base Seattle

What they're buying

This is a firm-fixed-price order, and all work must be finished within 45 calendar days.

Top catches

Solicitation number differs
“with solicitation RFQ number 70ZL3227Q20190002 in subject line” Notice text

The SAM.gov record shows 70Z0L3227Q20190002 with a zero. The notice text and SF 1449 show 70ZL3227Q20190002 with the letter L. Use the exact number the notice asks for in the subject line, and ask the Contracting Officer to confirm it if unsure.

Award basis conflicts
“provides the lowest priced, technically acceptable (LPTA) quote meeting the specifications of the requirement” Notice text

The notice says the lowest priced, technically acceptable quote wins. The provisions file describes an award based on price and other factors, and its evaluation box is not checked. Ask the Contracting Officer which basis applies before you decide how hard to price. Likely, not stated outright.

4 more catches below ↓

Read by AI (Claude Haiku) on Nov 25, 2026 from the notice and 5 of 6 attached files. Every quote on this page was found word for word in the source. Check the official notice before you bid.

The work

  • Annual service of fire extinguishers per NFPA 10 (SOW says 93 units)
  • Annual inspection of 5 wet-pipe sprinkler systems per NFPA 25, plus 6 one-year and 6 five-year internal pipe inspections
  • Testing of 2 FM-200 clean-agent systems (NFPA 2001), 4 ABC dry-chemical systems (NFPA 17), and 2 fire pumps (NFPA 20)
  • Annual fire alarm confidence tests per NFPA 72 (8 units) and annual testing of 11 fire panels
  • Final operational test in the presence of the Government point of contact, with a written certification and a final discrepancy report
  • Hangar systems per the NFPA 409 Chapter 11 table; the AFFF deluge system is locked out and excluded per Enclosure 2

Who did it before

No match in USAspending.gov: no contract at this agency for the same kind of work ends within a year either way.

What to watch for

  • Solicitation number differs. The SAM.gov record shows 70Z0L3227Q20190002 with a zero. The notice text and SF 1449 show 70ZL3227Q20190002 with the letter L. Use the exact number the notice asks for in the subject line, and ask the Contracting Officer to confirm it if unsure.
  • Award basis conflicts. The notice says the lowest priced, technically acceptable quote wins. The provisions file describes an award based on price and other factors, and its evaluation box is not checked. Ask the Contracting Officer which basis applies before you decide how hard to price.
  • SAM registration needed before award. You must be registered in SAM.gov before award. If you are not, the Contracting Officer moves on to the next offeror. Confirm your registration and size status before you spend time on the technical proposal.“Under FAR 4.1103 prospective contractor shall be registered in System Award Management (SAM) prior to award.” Notice text
  • Labor wage rules may apply. The Service Contract Labor Standards clause is marked as applying. One attached scanned file could not be read, and its name suggests a wage determination. Download that file from SAM.gov and price labor to it before you quote.“52.222-41 – Service Contract Labor Standards (Deviation)” 70ZL3227Q20190002_Provisions_Clauses.pdf, page 6
  • Start date for 45 days unclear. The SOW starts the 45 days at notice to proceed in one place and at award in another, and the proposal counts from the Notice to Award. Make sure your schedule fits 45 days, including final testing and the report, and ask which date starts the clock.“Contractor shall complete all work, deliverables and outcomes within 45 calendar days after notice to proceed is given by the Government” 70Z0L3227Q20190002_Scope of Work Fire System Inspection_2026.pdf, page 2
  • Counts and foam scope disagree. The SOW lists 93 extinguishers, but the counts in Enclosure 2 add up to 89. Enclosure 1 includes foam and deluge items, while Enclosure 2 says no work is needed on the AFFF deluge system, so confirm which hangar items you must price.“Fire Extinguisher Annual Service as per NFPA 10 (93 Units)” 70Z0L3227Q20190002_Scope of Work Fire System Inspection_2026.pdf, page 1

Key terms

Who can bidSmall businesses only (100% set-aside)The SF 1449 lists a size standard of $19.5 million. You must be registered in SAM.gov before award.Notice text
Contract periodNot more than 45 calendar daysThe start date is worded differently in two places. See the catches.70Z0L3227Q20190002_Scope of Work Fire System Inspection_2026.pdf, page 4
How they chooseLowest priced, technically acceptable (LPTA)The attached provisions describe a different basis. See the catches.Notice text
How to submitEmail to Patrick.R.Gittings@uscg.milSubject line must include RFQ number 70ZL3227Q20190002.Notice text
Questions dueTuesday, December 8, 2026, 3:00 p.m. PSTQuestions after this time will not be considered or answered.Notice text
Contract typeFirm-fixed-price purchase orderPrice all labor, materials, and tools. Corrective repairs and upgrades are not included unless the Contracting Officer authorizes them in writing.Notice text
Site visitFriday, December 4, 2026, at 1000 (no time zone given)Optional, but RSVP by email to DCC Jeremiah Randolph first. Arrive five minutes early.Notice text

How to respond

  1. Complete and sign the SF 1449. Fill in blocks 12, 17, 23, 24, and 30, with a breakdown of all costs and the total firm-fixed price in block 24.
  2. Write a technical proposal of no more than two pages. Include a step-by-step technical approach and a project schedule in days from the Notice to Award.
  3. Email the signed SF 1449 and the technical proposal to Patrick.R.Gittings@uscg.mil. Put RFQ number 70ZL3227Q20190002 in the subject line. Do not attach promotional or general company material.
  4. Send the email by Friday, December 11, 2026 at 3:00 p.m. PST. Late or incomplete submissions will not be considered.

Attached files

From SAM.gov. Download links open the original files.

Not stated in what we read

  • Estimated value of the purchase is not stated.
  • The scanned file SCWD+2015-5545+-+CLALLAM+WA+(5_13_2026)+(1).pdf could not be reviewed. Its contents, possibly wage rates, are unknown. You must read it on SAM.gov.
  • Which start date applies to the 45 days: notice to proceed or award.
  • The panel type for MFPU is listed as Unknown, and the 19 other extinguishers have no location.
  • The time zone for the site visit and any RSVP deadline are not stated.
  • Whether the hangar foam and deluge items in NFPA 409 Chapter 11 are in scope is not stated.

Notice text

DESCRIPTION OF REQUIREMENT: The U.S. Coast Guard requires annual inspection, testing, and maintenance of the fire protection systems for multiple facilities located at USCG AIRSTA Port Angeles. The work consists of providing all labor, equipment, material, transportation, supervision, items and services necessary for properly performing inspection, testing, and maintenance of fire protection systems in multiple buildings, including an aircraft hangar, in accordance with NFPA 11, NFPA 25, NFPA 70, NFPA 72, and NFPA 80 at Air Station Port Angeles.

The Government intends to issue a firm-fixed-price purchase order for this project. The full scope of work and specifications are included in the solicitation documents. PROJECT ADDRESS: U.S. Coast Guard Air Station Port Angeles 1 Ediz Hook Road Port Angeles, WA 98362 United States Classification: This acquisition is set-aside 100% for SMALL BUSINESS. The associated NAICS code is 541990 - Classified as All Other Professional, Scientific, and Technical Services cross referenced as Waterless fire suppression system testing and/or inspection, without sales, service, or installation.

The contract type will be firm fixed price purchase order. Where Federal Acquisition Regulation clause language is inconsistent with FAR 13.004, Legal Effect of Quotations, that language is hereby tailored in accordance with FAR 12.302 to be consistent with a request for quotations. This tailoring includes but is not limited to the following: In accordance with FAR 13.004, a quotation is not an offer, and any clause provision to the contrary is hereby modified to be consistent with FAR 13.004.

Where the word "offer/offeror" or a derivative of that word appears, it is changed to "quote/quoter" or a derivative of that word. Site Visit: A site visit will be held on Friday, December 4th. 2026 at 1000 for interested offerors. Interested offerors must RSVP by email to the technical point of contact, DCC Jeremiah Randolph, at Jeremiah.M.Randolph@uscg.mil. Attendees must arrive no later than five minutes before the scheduled start time. Offerors are strongly encouraged, but not required, to attend the site visit to develop an accurate and competitive quote.

Questions: Any and all questions regarding this solicitation shall be submitted in writing to the Contracting Officer at patrick.r.gittings@uscg.mil with solicitation RFQ number 70ZL3227Q20190002 in subject line. Questions regarding the statement of work (SOW) will be forwarded to the technical expert for an accurate response. All responses will be uploaded for an equal and fair solicitation to all interested vendors solely on SAM.gov. Questions received after 3:00 p.m. PST on December 8, 2026, will not be considered or answered.

Quote submission: Prohibition on Extraneous Material: Do not submit any unnecessary documents, promotional marketing materials, general company history brochures, or generic cover letters. Quotes must contain only the specific information requested below. Extraneous documents will not be evaluated. Quotes must be submitted electronically to patrick.r.gittings@uscg.mil by the date and time specified in this solicitation. Incomplete submissions may be considered unresponsive and submissions that fail to adhere to these instructions may be considered disqualified and ineligible for award.

A complete submission shall consist of the following parts: SF 1449: Complete and sign the provided Standard Form (SF) 1449. COMPLETE BLOCKS 12, 17, 23, 24, AND 30, with a breakdown of all costs and with the total firm-fixed-price bid in block 24. Technical Proposal: The Technical Proposal shall not exceed two (2) pages in length. It must provide a clear, concise narrative demonstrating the quoter’s understanding of and ability to meet the requirements of the Statement of Work (SOW).

The proposal must include: 1. Technical Approach: A step-by-step description of how the quoter will perform the work in accordance with the Scope of Work. 2. Project Schedule: A high-level timeline illustrating the project's major milestones. The schedule must start from the date of the Notice to Award (NTA) and demonstrate that all work, including performance verification and report submission, will be completed within the required Period of Performance.

Milestones should be shown in terms of days from the NTA (e.g., "Inspection of System(s) Complete: Day 3," "System(s) Repaired: Day 6," "Final Acceptance Testing: Day 9"). Submit quotes to the following E-mail Address Patrick.R.Gittings@uscg.mil with solicitation RFQ number 70ZL3227Q20190002 in the subject line. Date of offers due on 12/11/2026 at 3pm (PST). All offers that are submitted late (by day and time zone) and quotes that do not include a complete submission will not be considered in award determination.

Award: It is the government’s intent to award to the offeror who proposes a price that is fair and reasonable and provides the lowest priced, technically acceptable (LPTA) quote meeting the specifications of the requirement. If the lowest priced quote is not found to be technically acceptable, the contracting officer will evaluate the next lowest priced quote, and so on. Quotes determined to be incomplete, unreasonable, or unrealistic will not be considered for award.

Under FAR 4.1103 prospective contractor shall be registered in System Award Management (SAM) prior to award. Failure for contractor to be registered in SAM shall result in Contracting Officer to proceed with next successful registered offeror. Website: www.sam.gov.

As published on SAM.gov.

Contacts

As listed in the notice. Ask questions in writing and before the questions deadline, if the notice sets one.

History

  • Nov 25, 2026: first seen in the SAM.gov extract

SAM.gov shows only the latest version of a notice. FedLook keeps a copy of each day's notices and records what changed.

Free · at most one email a morning

Get new notices from US Coast Guard by email

Each morning we'll send the new solicitations and sources-sought notices from US Coast Guard, with deadlines and set-asides up front. Free. Unsubscribe in one click.

The morning edition by email: free, at most one email a morning, unsubscribe in one click. We use your address for nothing else and never share it. Privacy