- Opportunities
- Department of Veterans Affairs
- 36C25927Q0063
Annual boiler maintenance at Aurora VA medical center, CO
The VA Network Contracting Office 19 is surveying suppliers for annual boiler inspection, testing, and repair at the Rocky Mountain Regional VA Medical Center in Aurora, Colorado, for one base year and four option years.
Official title: J045--Annual Boiler Maintenance RMR VAMC
- Deadline
- Dec 4, 4:00 PM ET
- 9 days left
- Who can respond
- Any business
- Market research, not a bid
- Last time
- None found
- No contract like it at this agency in USAspending.gov
- Place
- Aurora
- Buyer: Network Contract Office 19 (36C259)
What they're buying
This is a market survey only, and you must email your response by 4:00 pm ET on Friday, December 4, 2026.
Top catches
“If this information is not provided, then it will be assumed the entire requirement cannot be met.” Notice text
If you leave out the questionnaire, the agency will assume the entire requirement cannot be met. Fill in every field, including size, UEI and the Buy American and subcontracting answers.
“be Cleaver Brooks factory trained” Draft SOW_Annual Boiler Maint.doc
Each technician must have one year of trade school, five years of experience, and Cleaver Brooks factory training. Confirm your crew meets this before you respond, since the facility manager may accept only equivalent qualifications.
Read by AI (Claude Haiku) on Nov 25, 2026 from the notice and 1 of 2 attached files. Every quote on this page was found word for word in the source. Check the official notice before you bid.
The work
- Annual internal and external inspection of boilers 1 to 4 and the de-aerator tank, with a written report in Word format within one week of each visit.
- Combustion tuning, safety device testing and instrument calibration every six months. Combustion tuning must be done a week after annual inspections.
- Safety pressure relief valve testing and certification at least twice a year.
- Magnetic particle test on the de-aerator every six years, first in the base year. Blower motor removal and inspection twice a year.
- Repair quotes within 5 business days of discovery. Emergency response within four hours, including after hours, weekends and holidays.
- Unscheduled maintenance and parts, paid per job, and checks or replacement of O2 sensors.
Who did it before
No match in USAspending.gov: no contract at this agency for the same kind of work ends within a year either way.
What to watch for
- Missing questionnaire means no fit. If you leave out the questionnaire, the agency will assume the entire requirement cannot be met. Fill in every field, including size, UEI and the Buy American and subcontracting answers.
- Cleaver Brooks factory training required. Each technician must have one year of trade school, five years of experience, and Cleaver Brooks factory training. Confirm your crew meets this before you respond, since the facility manager may accept only equivalent qualifications.
- No government equipment or materials. You must supply all tools, equipment, materials, transportation and personnel. Price all of these into your response, because the agency will not supply any of them.“The Government will not furnish any resources for the fulfillment of the services required under this contract.” Draft SOW_Annual Boiler Maint.doc
- Four-hour emergency response with cap. You must answer emergency calls within four hours, including after hours and on weekends. Emergency calls are capped at $20k per year, and the notice gives no amounts for repair limits, so price your on-call staffing carefully.“The contractor must respond to emergency call back service, within four hours or less” Draft SOW_Annual Boiler Maint.doc
- Size standard is $19.0 million. VA lists NAICS 238220 with a small business size of $19.0 million or less. Check your own size against this figure before you claim small business status, since the notice does not state a set-aside.“with a Small Business size of $19.0 Million or less” Notice text
Key terms
| Contract period | 1 base year plus 4 option yearsThe provided text gives no prices or dates for the option years.Draft SOW_Annual Boiler Maint.doc |
|---|---|
| How they choose | No award made from this noticeThis notice is for market research. It does not start a solicitation.Notice text |
| How to submit | Email to Christopher.Hollingsworth2@va.govLimit is 8 pages, including the cover letter. Mark it as proprietary if business sensitive.Notice text |
How to respond
- Complete the market research questionnaire in the notice, including NAICS code, company name, UEI, business size, and the Buy American and subcontracting answers.
- Write an overview of your proposed solution and a capabilities or qualifications statement that refers to the draft statement of work and the Salient Characteristics List.
- Keep the whole response to 8 pages or fewer, including the cover letter. Mark it as proprietary if it is business sensitive.
- Email the response to Christopher.Hollingsworth2@va.gov by 4:00 pm ET on Friday, December 4, 2026.
Attached files
From SAM.gov. Download links open the original files.
- Draft SOW_Annual Boiler Maint.docThis is the draft statement of work for the boiler work. You do not sign it, but you should read it closely because it sets out the work, qualifications and response times you must price. Read.
- https://sam.gov/api/prod/opps/v3/opportunities/resources/files/c0f32b9717a9421ea82c68106f3b73ce/download Could not be read.
Not stated in what we read
- Estimated value or budget for the contract.
- The content of the second attached file at the SAM.gov download link. We could not read it, so you must review it yourself.
- Set-aside status and whether the work is reserved for small businesses.
- Dollar amounts for the CLINs, including repair limits and unscheduled maintenance.
- Current contractor or incumbent details.
- Whether a site visit or pre-response meeting will be held.
Notice text
Sources Sought Notice Sources Sought Notice Page 6 of 6 Sources Sought Notice *= Required Field Sources Sought Notice Page 1 of 6 Sources Sought Notice Boiler Maintenance Disclaimer: This Request for Information (RFI) is issued solely for market research information and planning purposes and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responses to this notice are NOT offers and cannot be accepted by the Government to form a binding contract.
Responders are solely responsible for all expenses associated with responding to this RFI. Information Requested from Industry: In response to the Sources Sought, interested Contractors shall submit the following information and any Capabilities/Qualifications Statement to include but not limited to an overview of proposed solution(s) and a description of the product your company possesses in accordance with the attached Statement of Work draft / Salient Characteristics List.
Responses to market research table questionnaire shall be submitted. If this information is not provided, then it will be assumed the entire requirement cannot be met. Description of Requirement: The Department of Veterans Affairs, Veterans Health Administration (VHA), Network Contracting Office 19 (NCO 19) is conducting a market survey and is seeking potential sources for Boiler Maintenance at the Rocky Mountain Regional VA Medical Center. This Sources Sought Notice is issued for information and planning purposes only.
This is not a solicitation or a request for proposal and shall not be construed as an obligation or commitment by the Government. An award will not be made on any offer submitted in response to this notice, and it shall not be implied that the Government is committed to providing any solicitation or award following this notice. The Government will not pay for any information received in response to this request, nor will the Government compensate a respondent for any costs incurred in developing the information provided.
Requirement Services: Item No. Item Description 0001 Annual Boiler Maintenance (Base +4 Option Years) 0002 Unscheduled Maintenance and Parts (Base +4 Option Years) See attached statement of work In response to this announcement, please provide the information requested below requested in this market research table questionnaire. If this information is not provided, then it will be assumed the entire requirement cannot be met: NAICS Code: Company Name: Address: UEI (Unique Entity ID) Number: Contact Name: Phone No.: Email: Business Size Information - Select all that applies: Small Business Emerging Small Business Small Disadvantaged Business Certified under Section 8(a) of the Small Business Act HUBZone Woman Owned Certified Service-Disabled Veteran Owned Small Veteran Owned Small Business Large Business FSS/GSA Contract Holder: Yes No FSS/GSA Contract Number: Effective Date/ Expiration Date: Proposed solution is listed and available on the above FSS/GSA Contract: Yes No Available pricing structure of proposed solution (select all that are applicable below, or remove to fit your requirement): Pricing Model Please Indicate Availability Below: (Yes / No / NA) All on FSS Open Market only Mix of FSS & Open Market Firm-Fixed Price Federal Acquisition Regulation (FAR) Market Rearch Questions: Buy American Act RFO 52.225-1 and RFO 52.225-2 Buy American Certificate What percentage of the proposed product (including leases and rentals) is a: Domestic end product? _____________ (%) Foreign end product? _______________ (%) Country of Origin: Questions for Small Businesses ONLY: Limitations on Subcontracting RFO 52.219-14 What percentage of the work would be subcontracted to another company? ________ What is the business size of the subcontractor?______ Per RFO 52.219-14 the following conditions must be met: Services (except construction), it will not pay more than 50 percent of the amount paid by the Government for contract performance to subcontractors that are not similarly situated entities.
Any work that a similarly situated entity further subcontracts will count towards the prime contractor's 50 percent subcontract amount that cannot be exceeded. When a contract includes both services and supplies, the 50 percent limitation shall apply only to the service portion of the contract; Supplies (other than procurement from a nonmanufacturer of such supplies), it will not pay more than 50 percent of the amount paid by the Government for contract performance, excluding the cost of materials, to subcontractors that are not similarly situated entities.
Any work that a similarly situated entity further subcontracts will count towards the prime contractor's 50 percent subcontract amount that cannot be exceeded. When a contract includes both supplies and services, the 50 percent limitation shall apply only to the supply portion of the contract; If subcontracting, what added value do you offer (RFO 52.215-23): Nonmanufacturer Rule (RFO 52.219-33): Does your company manufacturer these proposed items? [Â ] yes [Â ] no Does your company exceed 500 employees? [Â ] yes [Â ] no If yes, list # of employees: _________ Does your company primarily engaged in the retail or wholesale trade and normally sells the type of item being supplied? [Â ] yes [Â ] no Does your company take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice? [Â ] yes [Â ] no Does your company supply the end item of a small business manufacturer, processor or producer made in the United States, or obtains a waiver of such requirement pursuant to paragraph (b)(5) CFR 121.406. [Â ] yes [Â ] no If yes, what is the manufacturer s name? ________________ Response Instructions: Do not provide more than 8 pages, including cover letter page.
Submit your response via email to Christopher.Hollingsworth2@va.gov Submit your response NLT 4:00pm (ET) on Friday, December 4, 2026; Mark your response as Proprietary Information if the information is considered business sensitive. VA has identified the appropriate North American Industry Classification System (NAICS) Code as 238220 Plumbing, Heating, and Air-Conditioning Contractors with a Small Business size of $19.0 Million or less. Please identify and explain any NAICS codes your company believes would better represent the predominant work included in the attached Statement of Work draft / Salient Characteristics List.
(End of Sources Sought)
As published on SAM.gov.
Contacts
- Chris Hollingsworth, Contract Specialist, Christopher.Hollingsworth2@va.gov, (303)712-5724
As listed in the notice. Ask questions in writing and before the questions deadline, if the notice sets one.
History
- Nov 25, 2026: first seen in the SAM.gov extract
SAM.gov shows only the latest version of a notice. FedLook keeps a copy of each day's notices and records what changed.
Should you bid?
Dec 4, 4:00 PM ET9 days left
A free report for your company: whether you can bid, what to confirm first and who may hold the work now.
Get the free reportSimilar open notices
Open now under NAICS 238220, plumbing, heating, and air-conditioning contractors, soonest deadline first.
- Department of Veterans AffairsChiller System Maintenance
- Department of Veterans AffairsControls Preventive Maintenance
- Department of the ArmyReplace two air handling units at Watervliet Arsenal, NY
- Bureau of Engraving and PrintingReplace air pollution oxidizer at Fort Worth, TX
- Departmental OfficesFire sprinklers and alarms at Honaunau park dorm, HI
- Departmental OfficesHeating leak repair at refuge visitor center, Homer, AK
- Department of Veterans AffairsBrine tank maintenance and salt delivery, Loma Linda, CA
- Department of Veterans AffairsAnnual Chiller Maintenance & Remote 24/7 Monitoring
Free · at most one email a morning
Get new notices from Department of Veterans Affairs by email
Each morning we'll send the new solicitations and sources-sought notices from Department of Veterans Affairs, with deadlines and set-asides up front. Free. Unsubscribe in one click.
The morning edition by email: free, at most one email a morning, unsubscribe in one click. We use your address for nothing else and never share it. Privacy