1. Opportunities
  2. Department of Veterans Affairs
  3. 36C249-27-AP-1027

Generator switchgear testing, Murfreesboro, TN

The VA wants market research on one-time diagnostic testing of the generator switchgear at the Alvin C. York VA Medical Center in Murfreesboro, Tennessee, with a written report.

Official title: APT Generator Switchgear Testing – Alvin C. York VA Medical Center

Deadline
Tomorrow, 12:00 PM CT
Thursday, Nov 26
Who can respond
Any business
Market research, not a bid
Last time
None found
No contract like it at this agency in USAspending.gov
Place
Murfreesboro, TN
Buyer: 249-Network Contract Office 9 (36C249)

What they're buying

Work would run six months from award, but this notice is not a solicitation and asks for no pricing.

Top catches

Deadline conflicts across notice
“by November 24, 2026, at noon CT” Notice text

The SAM.gov record gives Thursday, November 26, 2026 at 12:00 -06:00, but the notice text says November 24 at noon CT. Treat the earlier date as the deadline and send your email by November 24.

Due date is Thanksgiving Day
“4th Thursday in November” SOW Qualus test APT Generator Switch gear.doc

November 26, 2026 is the fourth Thursday of November, which the SOW lists as Thanksgiving Day, a federal holiday. Do not plan to send your response that day.

4 more catches below ↓

Read by AI (Claude Haiku) on Nov 19, 2026 from the notice and 1 of 1 attached files. Every quote on this page was found word for word in the source. Check the official notice before you bid.

The work

  • Insulation resistance, polarity, ratio, excitation, burden and dielectric withstand tests on three current transformers
  • Insulation resistance, polarity, turns ratio, burden and dielectric withstand tests on two sets of potential transformers
  • Visual inspection, event log download, functional and protection element checks, and output contact checks on one SEL-351A relay
  • Up to eight hours of one technician's time to investigate reverse kVAR trips
  • A written report of findings with recommendations
  • All transportation, labor, parts, materials, tools and equipment needed for the work

Who did it before

No match in USAspending.gov: no contract at this agency for the same kind of work ends within a year either way.

What to watch for

  • Deadline conflicts across notice. The SAM.gov record gives Thursday, November 26, 2026 at 12:00 -06:00, but the notice text says November 24 at noon CT. Treat the earlier date as the deadline and send your email by November 24.
  • Due date is Thanksgiving Day. November 26, 2026 is the fourth Thursday of November, which the SOW lists as Thanksgiving Day, a federal holiday. Do not plan to send your response that day.
  • Scope differs from notice. The notice describes diagnostic testing and a report. The SOW also asks for design, labor and materials, and calls the job a repair. Ask the contracting officer which scope applies before you price it.“Provide all design, supervision, labor and materials to complete all requirements described in this SOW.” SOW Qualus test APT Generator Switch gear.doc
  • SOW recommends a named firm. The SOW recommends Qualus, a named firm, for the repair work. Ask the contracting officer whether the VA will open this work to other firms before you spend time on a response.“I highly recommend having Qualus perform the repair work requested in this SOW.” SOW Qualus test APT Generator Switch gear.doc
  • Certified technicians required. All work must be done by certified trained technicians, but the SOW does not name the certifications. Confirm which certifications your staff must hold and price any training or certification cost.“All work for the duration of the contract shall be performed by certified trained technicians.” SOW Qualus test APT Generator Switch gear.doc
  • Insurance limit not given. You must carry personal liability and property damage insurance at a limit the law requires, but the SOW gives no dollar amount. Check your current policy limits and price any increase before you bid.“personal liability and property damage insurance having coverage for a limit” SOW Qualus test APT Generator Switch gear.doc

Key terms

Who can bidNot stated; response asks for business size and SBA certificationSet-aside is not stated. The size standard for NAICS 541380 is $19 million.Notice text
Contract period6 months from date of awardWork starts as soon as the contract is awarded. Warranty runs one year from acceptance.SOW Qualus test APT Generator Switch gear.doc
How to submitEmail shania.kimbrough@va.gov, subject APT Generator Switchgear TestingThe email deadline conflicts with the SAM.gov deadline.Notice text
Contract typeService repair contractThe SOW calls it a service repair contract, but the notice describes diagnostic testing.SOW Qualus test APT Generator Switch gear.doc

How to respond

  1. Email shania.kimbrough@va.gov with the subject APT Generator Switchgear Testing.
  2. Include your company name, UEI, point of contact, business size and SBA certification, testing experience, and availability.
  3. State whether you would quote if solicited, who would do the field testing, and whether you need special software or access to the existing relay.
  4. Send your email by November 24, 2026, at noon CT. The SAM.gov record shows a later deadline of November 26, 2026, at 12:00 -06:00, so the earlier date is the safer one.
  5. Do not send pricing. The notice says no pricing is requested.

Attached files

From SAM.gov. Download links open the original files.

Not stated in what we read

  • Estimated value or budget for the work.
  • Whether the acquisition will be set aside and which size standard applies.
  • Whether a solicitation will follow and when.
  • Required technician certifications and the insurance limit.
  • Whether a site visit or pre-bid meeting is required.
  • Whether Qualus is the current contractor or incumbent.

Notice text

The Department of Veterans Affairs, Network Contracting Office 9, seeks capable sources for one-time diagnostic testing of APT generator switchgear at the Alvin C. York VA Medical Center in Murfreesboro, Tennessee. The work includes testing three current transformers, two sets of potential transformers, and one SEL-351A protective relay; providing up to eight technician hours to investigate reverse kVAR trips; and submitting a written report with findings and recommendations.

Anticipated classification: NAICS 541380, Testing Laboratories and Services ($19 million size standard); PSC H261. Interested firms should email shania.kimbrough@va.gov by November 24, 2026, at noon CT, using the subject APT Generator Switchgear Testing. Include your company name, UEI, point of contact, business size and applicable SBA certification, relevant testing experience, and availability. State whether you would quote if solicited, who would perform the field testing, and whether you need any special software or access to the existing relay.

This notice is for market research only. It is not a solicitation or a commitment to award. No pricing is requested.

As published on SAM.gov.

Contacts

As listed in the notice. Ask questions in writing and before the questions deadline, if the notice sets one.

History

  • Nov 17, 2026: first seen in the SAM.gov extract

SAM.gov shows only the latest version of a notice. FedLook keeps a copy of each day's notices and records what changed.

Free · at most one email a morning

Get new notices from Department of Veterans Affairs by email

Each morning we'll send the new solicitations and sources-sought notices from Department of Veterans Affairs, with deadlines and set-asides up front. Free. Unsubscribe in one click.

The morning edition by email: free, at most one email a morning, unsubscribe in one click. We use your address for nothing else and never share it. Privacy