Capstan maintenance and load testing at NSA Portsmouth, VA
NAVFAC Mid-Atlantic is asking companies to submit capability statements for a planned IDIQ contract to inspect, maintain, certify and load-test capstans at NSA Portsmouth, VA, with a total term of up to 60 months.
Official title: CAPSTAN MAINTENANCE SERVICES AT NAVAL SUPPORT ACTIVITY (NSA), PORTSMOUTH, VIRGINIA
- Deadline
- Nov 30, 2:00 PM ET
- 5 days left
- Who can respond
- Any business
- Market research, not a bid
- Last time
- $124K
- Likely Mechanical Resources Incorporated
- Place
- Portsmouth, VA
- Buyer: Navfacsyscom Mid-Atlantic
What they're buying
This is market research only, not a solicitation, and the Government has not yet decided whether to set the work aside for small business.
Top catches
“The Offeror or, if a small business Offeror, its small business first-tier subcontractor, shall have been the prime contractor on all submitted projects.” Notice text
Projects count only if you were the prime, or a named small business first-tier subcontractor was the prime. Large-business subcontractor work does not count. Check your three to five projects before you respond.
“PAGES IN EXCESS OF THE TEN (10) PAGE LIMIT WILL NOT BE CONSIDERED.” Notice text
Pages beyond ten will not be considered. The notice does not say whether the two forms count toward the ten pages, so keep the core package well under ten pages and include both completed forms.
Read by AI (Claude Haiku) on Nov 21, 2026 from the notice and 2 of 2 attached files. Every quote on this page was found word for word in the source. Check the official notice before you bid.
The work
- Operational inspections before use of conventional and portable capstans, including controllers and foundation bases, checking rotation and emergency stop.
- Annual preventive maintenance, including gas-freeing conventional capstan pits before entry, pit or sump pump checks, and electrical checks such as megger testing and incoming voltage (480V +/- 5%).
- Gearbox oil sampling and replacement with laboratory analysis reports, plus brake and gearbox maintenance per the manufacturer's O&M Manual.
- Surface work on rusted areas: wire brushing, priming and painting.
- Load test certification every 4 years: dynamic and static tests at 85% to 125% of rated capacity, using a pulling rope rated at least 200,000 lbs and a dynamometer with 5% accuracy.
- Certification packages verified and signed off by a qualified Inspector, NAVSEA Dry Dock Engineering, and a NAVFAC Certification Officer.
Who did it before
$124K
on the contract that likely holds this work now: Mechanical Resources Incorporated. It ended Sep 30, 2026.
Matched in USAspending.gov by agency, NAICS and service code; notices rarely name the contractor.
What to watch for
- Only prime-contract experience counts. Projects count only if you were the prime, or a named small business first-tier subcontractor was the prime. Large-business subcontractor work does not count. Check your three to five projects before you respond.
- Ten-page limit and two forms. Pages beyond ten will not be considered. The notice does not say whether the two forms count toward the ten pages, so keep the core package well under ten pages and include both completed forms.
- Small business size standard applies. Your firm must be small under the $8 million size standard for NAICS 811310. If a set-aside is used, FAR 52.219-14 limits how much work you can subcontract. That clause is cited but not included, so read it before you price.“If the resulting solicitation is set aside for small business firms, it will include FAR 52.219-14, Limitations on Subcontracting.” Notice text
- UEI or DUNS number? The notice asks for a UEI number, but the contractor form has a DUNS field. Ask the contract specialist which identifier the form needs, and include your UEI and CAGE code in your profile.“Unique Entity Identification (UEI) number” Notice text
- Certified technicians and sign-offs needed. All inspection, maintenance and testing must be done by trained and certified technicians. Certification packages need three separate sign-offs. Confirm you can staff and certify this work before you respond.“Certification packages must be verified and signed off by a qualified Inspector, NAVSEA Dry Dock Engineering, and a NAVFAC Certification Officer.” Notice text
- Firm fixed price carries cost risk. Pricing is intended to be firm fixed price, so you may carry cost increases. The notice does not mention price adjustments, so assume none. Price the every-4-year load tests into your rates.“The contract is intended to be entirely FFP and IDIQ work ordered as required for recurring and non-recurring services.” Notice text
Key terms
| Who can bid | Small businesses encouraged; large businesses not consideredThe set-aside decision is not made yet. The Government will decide after it reviews responses.Notice text |
|---|---|
| Contract period | Up to 60 months, including any optionsAnticipated award is September 2027.Notice text |
| How to submit | Email capability package to emily.a.grissom.civ@us.navy.milAttention Emily Grissom, Contract Specialist. Package limit is 10 pages, plus two forms.Notice text |
| Contract type | Firm-fixed-price IDIQ, work ordered as neededIDIQ means work is ordered by task as required, with no guaranteed quantity stated.Notice text |
How to respond
- Confirm your size status under the $8 million size standard for NAICS 811310, and gather your UEI and CAGE code.
- Prepare a package of no more than 10 pages, single-sided, single-spaced, 12 point font minimum. Cover your company profile and three to five relevant contracts where you were the prime.
- Complete the Contractor Information Form and one Experience Data Form per project. Do not change the form content.
- Email the package to emily.a.grissom.civ@us.navy.mil, Attn: Emily Grissom, Contract Specialist, so it is received by 2:00 PM Eastern Standard Time on November 30, 2026.
Attached files
From SAM.gov. Download links open the original files.
- Project Data Form.docxExperience data form, one per project for up to five projects. It asks for contract details, customer contacts and a project description. You must fill it in and send it with your package. Read.
- Contractor Information Form.docxCompany information form with identifiers, contacts, business type and bonding fields. You must fill it in and send it with your package, though the notice does not mention bonding requirements. Read.
Not stated in what we read
- Estimated contract value.
- Whether the work will be set aside for small business, which the Government will decide after responses.
- Whether the two forms count toward the 10-page limit.
- Whether a solicitation will be issued, and when.
- Exact award date and start of performance, beyond anticipated award in September 2027.
- Deadline for questions about this notice.
Notice text
THIS IS A SOURCES SOUGHT NOTICE ONLY. This notice does NOT constitute a request for proposal, request for quote, or invitation for bid. There will not be a solicitation, specifications, or drawings available at this time. This notice is a market research tool used for planning purposes only to determine the availability and capability of businesses. Naval Facilities Engineering Systems Command, (NAVFAC) Mid-Atlantic is seeking Small Business, Small Disadvantaged Business, Women Owned Small Business, Service-Disabled Veteran-Owned Small Business, certified HUBZone Small Business, and certified 8(a) Businesses are encouraged to respond.
Upon review of industry response to this Sources Sought Notice, the Government will determine whether a set-aside acquisition in lieu of full and open competition is in the best interest of the Government. Large business submittals will not be considered. The Government is not obligated to and will not pay for any information received from potential sources as a result of this notice. The information provided in this notice is subject to change and in no way binds the Government to solicit for or award a contract.
The Government will not provide debriefs on the results of this research, but feedback regarding the decision to set aside or not set aside the procurement will be accomplished via pre-solicitation synopsis or solicitation for these services, as applicable. All information submitted will be held in a confidential manner and will only be used for the purpose intended. A Facility Support, Indefinite Delivery/Indefinite Quantity (IDIQ) Contract with recurring and non-recurring services is anticipated.
The total contract term, including the exercise of any options, shall not exceed 60 months. The Contractor shall provide all labor, management, supervision, tools, materials and equipment required to perform Capstan Maintenance Services on Naval Support Activity (NSA) Portsmouth, Portsmouth, VA. GENERAL REQUIREMENTS: NAVFAC Mid-Atlantic, is seeking qualified companies that can provide all labor, supervision, tools, materials, equipment and transportation necessary to perform inspection, maintenance, and certification of Capstan Maintenance Services at NSA Portsmouth, Portsmouth, VA. SPECIFIC REQUIREMENTS: The Contactor shall efficiently inspect, maintain and certify Capstan Maintenance Services.
The contract is intended to be entirely FFP and IDIQ work ordered as required for recurring and non-recurring services. The anticipated award is September 2027. NAICS CODE: The North American Industry Classification Standard (NAICS) code for this procurement is 811310, Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance, having a small business size standard of $8 million. If the resulting solicitation is set aside for small business firms, it will include FAR 52.219-14, Limitations on Subcontracting.
If adequate interest is not received from Small Business concerns, the solicitation will be issued as unrestricted without further notice. SUBMITTAL REQUIREMENTS: It is requested that interested businesses capable of providing the services sought submit to the contracting office a brief capabilities statement package (no more than 10 pages in length, single-sided, single-spaced, 12 point font minimum) demonstrating the ability to perform the requested services.
Interested sources are invited to respond to this Sources Sought Notice by using the forms provided under separate files total Sources Sought Contractor Information Form (form attached) and Experience Data Form (form attached). These forms are required. Information not provided may prohibit your firm from consideration. If you are submitting as a mentor-protégé joint venture under the 8(a) program, you must provide SBA approval of the mentor-protégé agreement to be considered as small for this procurement.
For more information on the definitions or requirements for these small business programs refer to http://www.sba.gov/. Responses must include identification and verification of the firm’s small business status. The capability package must be complete and sufficiently detailed to allow the Government to determine the firm's qualifications to perform the defined work. PAGES IN EXCESS OF THE TEN (10) PAGE LIMIT WILL NOT BE CONSIDERED. Respondents will not be notified of the results of the evaluation.
The documentation shall address, at a minimum, the following: COMPANY PROFILE to include: (1) Company name and address. (2) Year the firm was established and number of employees. (3) Names of two principals to contact (including title, telephone and fax numbers, and email addresses) (4) Unique Entity Identification (UEI) number (5) Commercial and Government Entity (CAGE) code number (6) If applicable, Small Business designation/status (e.g., 8(a), HUBZone, Service Disabled Veteran-Owned Small Business, Woman Owned Small Business, et cetera).
RELEVANT EXPERIENCE in performing efforts of similar scope, and complexity. Submit a minimum of three (3) up to a maximum of five (5) relevant contracts your firm has performed to best demonstrate your experience on relevant projects that are similar in scope and complexity. With the exception of 13 CFR 125.2(g) below, experience of proposed subcontractors will not be considered. Furthermore, the Offeror’s experience as a subcontractor will not be considered.
The following Government or commercial information shall be provided for each of your relevant experiences: (1) Contract number and project title. (2) Name of contracting activity (3) Contract period of performance and contract value (4) Brief summary of work performed and how it relates to the technical services sought by this Request for Information SCOPE/COMPLEXITY: The Contractor shall perform inspection, preventive maintenance (PM), repair, and load test certification on Conventional and Portable Capstans (including controllers and foundation bases) in accordance with the manufacturer's Operations & Maintenance (O&M) Manuals, NAVFAC standards, and Production Facility Manual (PFM) Chapter VI-A-9.
All inspection, maintenance, and testing activities must be executed by trained and certified mechanical and electrical technicians. Certification packages must be verified and signed off by a qualified Inspector, NAVSEA Dry Dock Engineering, and a NAVFAC Certification Officer. Inspection, Maintenance, and Certification includes: Operational Inspections: Perform condition and operational inspections prior to use. Inspect the mechanical and structural condition of capstans, drums, motors, foundations, fasteners, and controllers, and verify proper rotation and emergency stop functions.
Annual Preventive Maintenance (PM): Perform comprehensive annual maintenance including gas-freeing conventional capstan pits prior to entry, checking pit/sump pump drainage, and inspecting cover components. Electrical PM includes checking for arching, burns, pitting, loose connections, blade-to-contact misalignment, and loose fuses. Perform megger testing on incoming cables and motor leads (minimum acceptable value of 1 M? / 0.001 G?) and measure incoming voltage (acceptable range: 480V ± 5%).
Perform oil sampling/replacement for gearboxes (providing laboratory analysis reports), and execute brake, gearbox, and surface maintenance (wire brushing, priming, and painting rusted areas) in accordance with the O&M Manual. Load Test Certification (Every 4 Years): Perform dynamic and static load tests every 4 years and/or following any major structural modifications or repairs. Load testing must establish a line pull between 85% and 125% of the Manufacturer’s Rated Capacity (MRC) using a pulling rope rated for a minimum tensile strength of 200,000 lbs (100 Tons) and a calibrated dynamometer with 5% accuracy installed in the pulling line.
Dynamic Load Testing (DLT): Successfully achieve the MRC range (85% to 125%) 3 consecutive times utilizing the capstan motor. Static Load Testing (SLT): Verify brake hold capacity at the MRC range 3 consecutive times utilizing an external tension source. The brake load must hold for 5 minutes without dropping more than 5% of the starting brake load. A trained and certified technician shall perform all inspections, maintenance, and load-test certifications for all Conventional and Portable Capstan systems in accordance with established Navy, safety, and industry regulations.
Failure to use such qualified personnel does not fulfill requirements and places all responsibility and liability on the third-party inspector/certifier. For purposes of evaluating capability, the “Offeror” is defined as the prime contractor that demonstrates experience on relevant projects that meet scope and complexity. In accordance with 13 CFR 125.2(g), small business Offerors may utilize the experience of a small business first-tier subcontractor(s) to demonstrate experience under this capability evaluation if the Offeror cannot independently satisfy the experience requirement as defined above.
In order to utilize the experience of a small business first-tier subcontractor(s), the offeror must specifically identify the proposed small business first-tier contractor(s) in its capability package in accordance with this notice. The Offeror or, if a small business Offeror, its small business first-tier subcontractor, shall have been the prime contractor on all submitted projects. The Government notes that 13 CFR 125.2(g) is specific to only small business Offerors and named small business first-tier subcontractors.
As such, the small business Offeror is not permitted to use the experience of a large business subcontractor or large business corporate affiliate in place of its own if the small business Offeror cannot independently satisfy the experience requirement as defined above. Responses to this Sources Sought Notice shall be emailed to the following email address: emily.a.grissom.civ@us.navy.mil Attn: Emily Grissom, Contract Specialist Responses must be received no later than 2:00 PM Eastern Standard Time on November 30, 2026.
Questions regarding this sources sought notice may be addressed to Emily Grissom at emily.a.grissom.civ@us.navy.mil. The Government will use responses to this Sources Sought Notice to make appropriate acquisition decisions. The Capabilities Statement for this Sources Sought is not expected to be a proposal, but rather short statements regarding the company’s ability to demonstrate existing-or-developed expertise and experience in relation to the areas specified herein.
Submission of Capabilities Statement is not a prerequisite to any potential future offerings, but participation will assist the Government in tailoring requirements to be consistent with industry capabilities. NOTE: The findings from this Market Research effort may impact any future solicitations related to this requirement. This Market Research is not a solicitation as defined by FAR 2.101 and the Government is not requesting offers or bids at this time.
This is a Request for Information and does not constitute a solicitation or invitation for bid. Any responses to this Request for Information received by the Government will not be accepted to form a binding contract. This is a market survey for planning purposes and no award will be made as a result of this Sources Sought Notice. If a solicitation is issued, the Government does not guarantee that it will be issued to Request for Information respondents.
The Government is also requesting that restrictive or proprietary markings not be used in response to the Request for Information. Funding is not available for any information or proposals submitted. Submitting information does not bind the Government for any future contracts resulting from this Request for Information.
As published on SAM.gov.
Contacts
- Emily Grissom, emily.a.grissom.civ@us.navy.mil, 757-761-0262
- Rachel Honecker, rachel.n.honecker.civ@us.navy.mil, 7573961010
As listed in the notice. Ask questions in writing and before the questions deadline, if the notice sets one.
Who may hold this work now
Contracts at Department of the Navy for the same kind of work (NAICS 811310, service code J040) in Virginia that end within a year either way of today. Notices rarely name the current contractor: these are likely candidates, not a fact.
| Contract | Obligated | Ends | State |
|---|---|---|---|
| NSA Portsmouth FY26 Capstan Maintenance Funding Task Order (Pop 10/01/2025 - 09/30/2026)Mechanical Resources Incorporated · N4008526F0078 | $123,600 | Sep 30, 2026ended | VA |
Source: USAspending.gov, prime contracts of $100,000 or more. Department of Defense contracts appear there about 90 days after award.
History
- Nov 17, 2026: first seen in the SAM.gov extract
SAM.gov shows only the latest version of a notice. FedLook keeps a copy of each day's notices and records what changed.
Should you bid?
Nov 30, 2:00 PM ET5 days left
A free report for your company: whether you can bid, what to confirm first and who may hold the work now.
Get the free reportSimilar open notices
Open now under NAICS 811310, commercial and industrial machinery and equipment (except automotive and electronic) repair and maintenance, soonest deadline first.
- Department of Veterans AffairsHood, fire system and extinguisher service, Little Rock, AR
- US Coast GuardReplace crane turntable bolts at Cape May, NJ
- Department of the ArmyHalon fire bottle testing at Jacksonville Air Guard, FL
- Department of the NavyFlow meter verification at Pearl Harbor shipyard, HI
- Department of the Air ForceReplace gate valve frame at Flag Lake, Barksdale AFB, LA
- Department of the ArmyMaterial handling and industrial equipment repair
- Department of the Air ForceRepair of Sciaky spot welder at Tinker AFB, OK
- Department of the NavyFire extinguisher hydrostatic testing at Iwakuni, Japan
Free · at most one email a morning
Get new notices from Department of the Navy by email
Each morning we'll send the new solicitations and sources-sought notices from Department of the Navy, with deadlines and set-asides up front. Free. Unsubscribe in one click.
The morning edition by email: free, at most one email a morning, unsubscribe in one click. We use your address for nothing else and never share it. Privacy