Diesel generator service at Bronx VA medical center, NY
The Department of Veterans Affairs (VA) James J. Peters Medical Center in Bronx, NY wants information from firms that can inspect, maintain and repair its nine diesel generators for one six-month period.
Official title: J030--Diesel Generator Service
- Deadline
- Dec 3, 4:00 PM ET
- 7 days left
- Who can respond
- Any business
- Market research, not a bid
- Last time
- $290K
- Likely H. O. Penn Machinery Company, Inc.
- Place
- Bronx, NY
- Buyer: 242-Network Contract Office 02 (36C242)
What they're buying
This is a sources sought notice for market research only, and the government does not intend to award a contract from it.
Top catches
“The Government does not intend to award a contract on the basis of this Sources Sought or to otherwise pay for the information solicited.” Notice text
This notice gathers market information only, and the government says it will not award a contract from it. Reply with the capability details requested, and treat any later solicitation as a separate step.
“If any of the requested information is not supplied with the response, the contractor may not be considered in the Government s Procurement Strategy.” Notice text
If you leave out any requested item, the government may not consider you. Gather the full list before you send your reply by the deadline.
Read by AI (Claude Haiku) on Nov 26, 2026 from the notice and 2 of 2 attached files. Every quote on this page was found word for word in the source. Check the official notice before you bid.
The work
- Annual and semi-annual preventive maintenance on all nine generators, including inspections, tests, and manufacturer checklists
- One-time fuel-quality testing with a written lab report for each fuel-storage tank
- Oil and filter changes, coolant and battery checks, and battery replacement as needed
- On-site emergency repairs with response from 2 hours for life-safety events and 8 hours for urgent faults
- Written PM program within 45 days of award, and service reports to the COR by email in PDF within 48 hours
- Program-logic work on the Power Logic Control System that runs the 4160 V generator network
Who did it before
$290K
on the contract that likely holds this work now: H. O. Penn Machinery Company, Inc.. It ended Dec 20, 2025.
Matched in USAspending.gov by agency, NAICS and service code; notices rarely name the contractor.
What to watch for
- Sources sought, not a bid. This notice gathers market information only, and the government says it will not award a contract from it. Reply with the capability details requested, and treat any later solicitation as a separate step.
- Missing items may exclude you. If you leave out any requested item, the government may not consider you. Gather the full list before you send your reply by the deadline.
- Five years of PLC experience required. The SOW requires at least five years of experience with the PLC logic systems that control the generators. Confirm your record and list the contracts that prove it before you reply.“Contractors must have 5 years or more experience with programming and maintaining PLC Square D equivalent Logic Systems.” SOW Diesel Generator Service 11.17.docx
- Two-hour on-site emergency response. A life-safety failure needs a qualified technician on site within 2 hours of notice, and you must answer calls around the clock. Confirm you can staff that coverage before you commit to the work.“Within 2 hours of notification” SOW Diesel Generator Service 11.17.docx
- Repairs need written approval first. Repairs beyond the minor-repair limits need written approval from the contracting officer before work starts. Stabilization work you do without that approval is at your own financial risk.“The Contractor assumes financial risk for any stabilization labor performed without subsequent CO authorization.” SOW Diesel Generator Service 11.17.docx
- Set-aside and size still open. The notice does not say whether the work will be set aside, and it tests several small-business categories. Check that you meet the $12.5 million size standard and the category you hold before you reply.“Part of the purpose of this sources sought is to determine the viability of set aside to a specific socio-economic category” Notice text
Key terms
| Contract period | One six-month periodAnnual service within 30 days of award. Semi-annual service within the final 30 days.SOW Diesel Generator Service 11.17.docx |
|---|---|
| How to submit | Email to Chris Weider at Christopher.Weider@va.govInclude the items listed in the notice. Format and file type are not stated.Notice text |
| Contract type | Firm-fixed price for scheduled preventive maintenance; repairs need written approvalRepair labor rates come from a CLIN structure that the notice does not provide.SOW Diesel Generator Service 11.17.docx |
How to respond
- Gather your capability statement, SAM UEID, company contact, and examples of similar work with contract numbers and any subcontractors.
- Answer every item in the notice, including whether any tasks go to a subcontractor and which tasks you would perform as prime.
- Email the response to Chris Weider at Christopher.Weider@va.gov before 4:00 PM Eastern Time on Thursday, 12-03-2026.
- File format and size limits: Not stated. The notice says the response is information only and not a proposal.
Attached files
From SAM.gov. Download links open the original files.
- SOW Diesel Generator Service 11.17.docxThe statement of work listing the nine generators, maintenance tasks, repair and emergency rules, and reporting. You read it; no form needs signing. Read.
- 36C24227Q0163.docxThe notice form with the contracting office, response deadline, and contact details. You read it; no form needs signing. Read.
Not stated in what we read
- Estimated value or budget for the work
- Whether the work will be set aside, and for which category
- Whether a solicitation will follow this notice, and when
- Labor rates in the CLIN structure used for repairs
- Who supplies the back-up generator needed when work is done on a unit
- Serial numbers for Generac unit #3 (listed as TBD) and unit #5 (two options listed)
Notice text
Sources Sought Notice This Sources Sought is issued by the VISN 2 Contracting Office for the purpose of collecting information related to diesel generator service for the James J. Peters VA Medical Center in Bronx, NY. The NAICS code identified for this requirement is 811310, with a size standard of $12.5 million. The requirement is detailed in the attached Statement of Work. This is a Sources Sought Notice. The Government does not intend to award a contract on the basis of this Sources Sought or to otherwise pay for the information solicited.
Although "proposal," "offeror," contractor, and "offeror" may be used in this sources sought notice, any response will be treated as information only. It shall not be used as a proposal. The Government is seeking information for market research purposes only. Any information received from a contractor in response to this Sources Sought may be used in creating a solicitation. Any information received which is marked with a statement, such as "proprietary" or "confidential," intended to restrict distribution will not be distributed outside of the Government, except as required by law. Part of the purpose of this sources sought is to determine the viability of set aside to a specific socio-economic category (service-disabled veteran owned small business, veteran owned small business, women owned small business, HUB Zone, 8(a), small business).
Interested parties MUST provide: Company/individual name Address Point of contact capability statement Examples of same or similar work performed at other facilities, include contract numbers and subcontractors for those jobs if applicable. SAM UEID number (for Prime and Subcontractor, if applicable) Any applicable Federal Supply Schedules If your intention is to subcontract work, what tasks will be performed by the subcontractor due to your inability to perform them within your company?
If your intention is to subcontract work, what tasks will be performed by you as the prime contractor? Proof of any applicable certifications or training. Please indicate whether the certified individuals are employed by the prime or sub contractor. Any relevant comments about the Attachment(s) Contractors that are able to meet the requirements in the attachment and possess an interest in performing this service, are encouraged to email the above information to Chris Weider at Christopher.Weider@va.gov. If any of the requested information is not supplied with the response, the contractor may not be considered in the Government s Procurement Strategy.
As published on SAM.gov.
Contacts
- Chris Weider, Contract Specialist, Christopher.Weider@va.gov, (716) 862-7461 x22470
As listed in the notice. Ask questions in writing and before the questions deadline, if the notice sets one.
Who may hold this work now
Contracts at Department of Veterans Affairs for the same kind of work (NAICS 811310, service code J030) in New York that end within a year either way of today. Notices rarely name the current contractor: these are likely candidates, not a fact.
| Contract | Obligated | Ends | State |
|---|---|---|---|
| Generator & Equipment Maintenance & StorageH. O. Penn Machinery Company, Inc. · 36C24224P0401 | $289,531 | Dec 20, 2025ended | NY |
Source: USAspending.gov, prime contracts of $100,000 or more. Department of Defense contracts appear there about 90 days after award.
History
- Nov 26, 2026: first seen in the SAM.gov extract
SAM.gov shows only the latest version of a notice. FedLook keeps a copy of each day's notices and records what changed.
Should you bid?
Dec 3, 4:00 PM ET7 days left
A free report for your company: whether you can bid, what to confirm first and who may hold the work now.
Get the free reportSimilar open notices
Open now under NAICS 811310, commercial and industrial machinery and equipment (except automotive and electronic) repair and maintenance, soonest deadline first.
- Department of the ArmyHalon fire bottle testing at Jacksonville Air Guard, FL
- Department of the NavyFlow meter verification at Pearl Harbor shipyard, HI
- Department of the ArmyMaterial handling and industrial equipment repair
- Department of the Air ForceSciaky spot welder repair at Tinker AFB, OK
- Department of the NavyFire extinguisher hydrostatic testing at Iwakuni, Japan
- Department of the ArmyDiesel rotary UPS maintenance at USAG Humphreys
- US Coast GuardAttic exhaust fan replacement at Station Fire Island, NY
- Department of Veterans AffairsINTENT TO SOLE SOURCE Troubleshoot Desert Aire AHU Carel Controller
Free · at most one email a morning
Get new notices from Department of Veterans Affairs by email
Each morning we'll send the new solicitations and sources-sought notices from Department of Veterans Affairs, with deadlines and set-asides up front. Free. Unsubscribe in one click.
The morning edition by email: free, at most one email a morning, unsubscribe in one click. We use your address for nothing else and never share it. Privacy