- Opportunities
- Department of Homeland Security
- US Coast Guard
- 30199PR270000005
Attic exhaust fan replacement at Station Fire Island, NY
You would remove four attic exhaust fans, dampers and old controls at Station Fire Island in Babylon, NY, then install four new 115-volt exhaust fans with thermostat controls that reuse the existing vents and circuits.
Official title: USCG Station Fire Island Attic Vents
- Deadline
- Nov 30, 12:00 AM ET
- 4 days left
- Last time
- None found
- No contract like it at this agency in USAspending.gov
- Place
- Babylon, NY
- Buyer: Base Boston
What they're buying
All work must be complete within 30 calendar days after award, and labor must follow the attached Service Contract Act wage rates.
Top catches
“Response deadline: 2026-11-30T00:00:00-05:00” SAM.gov record
The deadline is 12:00 AM Monday, so the real cutoff is the end of Sunday, November 29. Submit well before then and confirm the time zone is Eastern.
“Greenheck SE1-12-DGEX-QD with Vari-Flow EC motor or equal” Station_Fire_Island_Exhaust_Fan_SOW_Revised.docx
The basis of design names an EC motor, but the electrical data lists a PSC motor. Ask the COR which motor is required before you price, and state your choice in the product data you submit.
Read by AI (Claude Haiku) on Nov 25, 2026 from the notice and 4 of 4 attached files. Every quote on this page was found word for word in the source. Check the official notice before you bid.
The work
- Remove four existing fans, motor-operated dampers and obsolete controls. Dispose of removed materials off Government property.
- Provide and install four new sidewall propeller exhaust fans (AEF-1 to AEF-4), each at least 500 CFM at 0.10 inch water gauge, 115 V single phase 60 Hz, with speed control and thermal overload protection.
- Provide backdraft dampers, duct transitions, sealed connections, hangers and fasteners to connect each fan to the existing louvered penthouses.
- Reuse existing branch circuits. Provide local wiring, conduit, junction boxes, disconnects and control connections. Label each fan and its circuit.
- Provide one adjustable thermostat and one manual continuous-operation control per fan, set to start on a temperature rise above 90 degrees F.
- Submit product data before procurement. Test all fans, verify at least 500 CFM per fan, and deliver manuals, test results, a fan and circuit record, and a one-year warranty on workmanship and equipment.
Who did it before
No match in USAspending.gov: no contract at this agency for the same kind of work ends within a year either way.
What to watch for
- Deadline falls at midnight. The deadline is 12:00 AM Monday, so the real cutoff is the end of Sunday, November 29. Submit well before then and confirm the time zone is Eastern.
- Motor type conflicts in the spec. The basis of design names an EC motor, but the electrical data lists a PSC motor. Ask the COR which motor is required before you price, and state your choice in the product data you submit.
- Key drawing not on attachment list. The scope says Drawing SK-1 governs some details and supersedes parts of it. It is not on the SAM.gov attachment list, so we could not review it. You must get it from the contracting office before you price.“Attachment 1 is Drawing SK-1, dated March 21, 2024, Project 26062571, provided for existing locations and applicable connection details.” Station_Fire_Island_Exhaust_Fan_SOW_Revised.docx
- Circuit upgrades are not in scope. You must confirm existing circuit capacity before installing. New circuits, panel upgrades and structural work are excluded, and such work would stop and go to the COR. Check circuit capacity at the site visit and before you price.“Confirm existing circuit capacity and equipment compatibility before installation; no new circuits, panel upgrades, structural reinforcement, or major duct rerouting are included.” Station_Fire_Island_Exhaust_Fan_SOW_Revised.docx
- 30 days for a multi-step job. Thirty calendar days must cover submittal review, Government acceptance before any installation, installation, testing and documentation. Work hours are Monday to Friday, 0800 to 1500 only. Plan crews and fan orders now.“Complete all work within 30 calendar days after contract award.” Station_Fire_Island_Exhaust_Fan_SOW_Revised.docx
- Wage rates set your labor cost. Price labor at the rates in wage determination 2015-4157, Revision 33, dated 8/12/2026. Examples include maintenance electrician at 37.99, HVAC mechanic at 37.50 and sheet-metal worker at 37.19, plus 5.92 per hour health and welfare. Confirm which classes fit your crew.“All wages and benefits must be in accordance with the wage rates for the Place of Preformance and Period Of Preformance.” Notice text
Key terms
| Who can bid | Open to all businesses (no set-aside)NAICS 811310 and PSC J039 are listed. The notice gives no size standard.SAM.gov record |
|---|---|
| Contract period | Work complete within 30 calendar days after contract awardFan installs must wait for Government acceptance of submittals, so this window is tight.Station_Fire_Island_Exhaust_Fan_SOW_Revised.docx |
| Site visit | Highly encouraged, not requiredCoordinate any visit with the COR and the unit Engineering Petty Officer.Station_Fire_Island_Exhaust_Fan_SOW_Revised.docx |
How to respond
- Ask the contracting office for Drawing SK-1 before you price. It is not on the SAM.gov attachment list, so we could not review it.
- Ask COR CWO2 Coyet A. Carter (Coyet.A.Carter@uscg.mil, (475) 301-1053) which motor is required, EC or PSC, and how to confirm existing circuit capacity.
- Price labor using wage determination 2015-4157 Revision 33 rates and the 5.92 per hour health and welfare rate. Confirm your trades match the listed classes.
- Submission method, address, format and any required forms: Not stated. Check the solicitation package on SAM.gov and send your offer well before Sunday, November 29.
- Plan product data submittals first. Installation cannot start until the Government reviews and accepts them, and all work must finish within 30 calendar days after award.
Attached files
From SAM.gov. Download links open the original files.
- Station_Fire_Island_Exhaust_Fan_SOW_Revised.docxThe scope of work for the fan replacement, with specifications, work hours, controls, submittal rules and COR contact. You must price and follow it. Read.
- WAR Clauses.docxA bundle of standard federal clauses and representations, including sanctions and covered telecommunications statements that you make by submitting an offer. Read these before you sign or submit. Read.
- Wage Rates 15-4157.txtService Contract Act wage determination 2015-4157, Revision 33, for Nassau and Suffolk counties in New York. Use these rates to price labor. You do not sign it. Read.
- DEI_FAR_Clause.docxA clause you must agree to. It bars racially discriminatory DEI activities by you and your subcontractors, and it says compliance is material to payment decisions. Read.
Not stated in what we read
- Estimated value of the work: Not stated.
- Contents of Drawing SK-1, which the SOW references but which is not on the attachment list.
- Award basis, such as lowest price or best value: Not stated.
- How, where and in what format to submit an offer: Not stated.
- Deadline for questions, and the contracting officer's name and contact details.
- Which domestic-preference clause applies. The SOW refers to one, but no attachment includes it.
Notice text
Removal and placement of attic ventalation fans in accordance with the attached Statement Of Work (SOW) All wages and benefits must be in accordance with the wage rates for the Place of Preformance and Period Of Preformance. Wage rates attached.
As published on SAM.gov.
Contacts
- Jeff Center, jeffery.a.center2@uscg.mil
- Kyle Swann, Kyle.D.Swann2@uscg.mil
As listed in the notice. Ask questions in writing and before the questions deadline, if the notice sets one.
History
- Nov 25, 2026: first seen in the SAM.gov extract
SAM.gov shows only the latest version of a notice. FedLook keeps a copy of each day's notices and records what changed.
Should you bid?
Nov 30, 12:00 AM ET4 days left
A free report for your company: whether you can bid, what to confirm first and who may hold the work now.
Get the free reportSimilar open notices
Open now under NAICS 811310, commercial and industrial machinery and equipment (except automotive and electronic) repair and maintenance, soonest deadline first.
- Department of Veterans AffairsHood, fire system and extinguisher service, Little Rock, AR
- US Coast GuardReplace crane turntable bolts at Cape May, NJ
- Department of the ArmyHalon fire bottle testing at Jacksonville Air Guard, FL
- Department of the NavyFlow meter verification at Pearl Harbor shipyard, HI
- Department of the Air ForceReplace gate valve frame at Flag Lake, Barksdale AFB, LA
- Department of the ArmyMaterial handling and industrial equipment repair
- Department of the Air ForceRepair of Sciaky spot welder at Tinker AFB, OK
- Department of the NavyFire extinguisher hydrostatic testing at Iwakuni, Japan
Free · at most one email a morning
Get new notices from US Coast Guard by email
Each morning we'll send the new solicitations and sources-sought notices from US Coast Guard, with deadlines and set-asides up front. Free. Unsubscribe in one click.
The morning edition by email: free, at most one email a morning, unsubscribe in one click. We use your address for nothing else and never share it. Privacy