- Opportunities
- Department of Veterans Affairs
- 36C26127Q0169
Hood cleaning and fire system checks, VA Palo Alto, CA
The VA Palo Alto Health Care System is seeking a contractor to clean, inspect and certify grease hoods, exhaust fans and chemical hazmat sheds with their fire suppression systems at three California sites.
Official title: J012--Dry-Type Fire Suppression System
- Deadline
- Nov 30, 3:00 PM PT
- 5 days left
- Who can respond
- Any business
- Market research, not a bid
- Last time
- None found
- No contract like it at this agency in USAspending.gov
- Place
- Palo Alto
- Buyer: 261-Network Contract Office 21 (36C261)
What they're buying
This is a sources sought notice, not a bid, so your reply is a capability statement due by 3:00 PM Pacific Time on Monday, November 30, 2026.
Top catches
“Contractor shall possess a California C-16 contractor license and be certified by the system manufacturer to service and repair Ansul and related Automatic Fire Control Systems, or provide documentation of equivalent system training.” Notice text
You must hold a California C-16 license and manufacturer certification for Ansul systems, or show equivalent training. Hood cleaners must hold IKECA or equivalent certification. Confirm these before you respond.
“Failure to provide the information requested above (items (a) (j)) will be considered non-responsive and will not be considered a viable source.” Notice text
If you leave out any item from (a) through (j), including copies of your certificates and licenses, your response will not be considered. Keep the whole response within 10 single-sided pages.
Read by AI (Claude Haiku) on Nov 18, 2026 from the notice and 2 of 2 attached files. Every quote on this page was found word for word in the source. Check the official notice before you bid.
The work
- Semi-annual and annual cleaning and certification of grease hoods, ducts and exhaust fans: 5 hoods at Palo Alto, 4 at Menlo Park and 1 at Livermore.
- Semi-annual and annual service and certification of automatic fire control systems for the hoods and hazmat sheds at all three sites.
- Semi-annual and annual certification of chemical hazardous material storage sheds with self-contained fire protection systems.
- Digital photos before and after each cleaning, labeled by division, building and hood identification.
- Replacement of failed parts with new components to meet NFPA codes, with model and serial numbers recorded. Parts up to $150 are included in the price.
- Written report for each hood and each hazmat container within 7 calendar days of each inspection, with four hard copies and one PDF to the Engineering Compliance Office.
Who did it before
No match in USAspending.gov: no contract at this agency for the same kind of work ends within a year either way.
What to watch for
- License and fire system certifications. You must hold a California C-16 license and manufacturer certification for Ansul systems, or show equivalent training. Hood cleaners must hold IKECA or equivalent certification. Confirm these before you respond.
- Missing items make you non-responsive. If you leave out any item from (a) through (j), including copies of your certificates and licenses, your response will not be considered. Keep the whole response within 10 single-sided pages.
- False alarm charges fall on you. If your work sets off a false alarm, you must pay the fire department's charges. Confirm alarm shutdown and restart with the COR before work starts, and log the times in writing.“Contractor shall be liable for any charges imposed by the responding fire departments” 36C26127Q0169.docx
- After-hours work at no extra charge. Normal hours are 7:00 AM to 3:30 PM, Monday to Friday. The attached schedule lists after-hours work times, and the notice says after-hours work is free, so price that time in and get the COR's arrangement in writing.“Contractor may work outside normal business hours by arrangement with the COR if such services are provided without additional charge to the government.” 36C26127Q0169.docx
- Parts above $150 need COR approval. Parts for preventive maintenance up to $150 are in your price. Above that, the government pays the difference only after the COR approves your quote, so plan for delays in getting paid for parts.“Government shall pay for a difference if total value of parts exceeds $150 after the contractor provides a quote to be approved by the COR.” 36C26127Q0169.docx
- Sites differ between SAM and notice. The SAM record lists only Palo Alto, but the notice and attached schedule also cover Menlo Park and Livermore. Price crews and travel for all three sites.“Place of performance: Palo Alto, 94304, USA” SAM.gov record
Key terms
| Who can bid | Not stated. You must be registered in SAM.Set-aside field is blank. Size standard is $12.5 million for NAICS 811310. Subcontractors that are not similarly situated can get no more than 50 percent of service payments.Notice text |
|---|---|
| How to submit | Email to Kulvinder.brar@va.govCapability statement of no more than 10 single-sided pages, 12-point font or larger.Notice text |
| Contract type | Firm fixed priceNon-personal services contract.36C26127Q0169.docx |
How to respond
- Confirm your SAM registration lists NAICS 811310 and that your Online Representations and Certifications Application is current.
- Gather your business size, socio-economic status, SAM record, VIP record if you are SDVOSB or VOSB, DUNS number, and copies of your C-16 license and manufacturer certifications.
- Write your response in no more than 10 single-sided pages, 12-point font or larger, covering items (a) through (j). Published literature may be any number of pages.
- Email the capability statement to Kulvinder.brar@va.gov by 3:00 PM Pacific Time on Monday, November 30, 2026.
- File format and any subject line: Not stated.
Attached files
From SAM.gov. Download links open the original files.
- 36C26127Q0169.docxNotice text and the performance work statement with scope, certification and reporting rules. You must read it; nothing to fill in. Read.
- Grease Hood-HAZMAT shed inventory-Schedule- bldg plans 7-24-206.pdfInventory, maintenance schedule and building plans for the hoods, fans and sheds. You must read it; nothing to fill in. Read.
Not stated in what we read
- Estimated contract value.
- Contract length and option years.
- Set-aside status, since the set-aside field is blank.
- When the solicitation will be posted and how responses will be evaluated.
- Whether a site visit or pre-bid meeting is required.
- File format and any subject line for the capability statement.
Notice text
THIS IS A SOURCES SOUGHT ANNOUNCEMENT ONLY. No Solicitation is currently available. All information contained in this Sources Sought Announcement is preliminary, as well as subject to modification, and is in no way binding on the Government. The Government will not pay for any information submitted in response to this request. The information requested will be used solely within the Department of Veterans Affairs to facilitate decision making and will not be disclosed outside of the Government.
The determination of a procurement strategy, based upon the comments submitted in response to this Sources Sought Announcement, is solely within the discretion of the Government. Potential Offerors must be registered in the System for Award Management (SAM) to be eligible for an award (See Internet Site https://www.sam.gov/portal/public/SAM/). Potential Offerors must also have a current Online Representations and Certification Application on file with SAM. The applicable North American Industry Classification System (NAICS) Code is 811310, Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance and size standard is $12.5 million.
NOTE: Please ensure that System For Award Management (SAM) indicates this NAICS code if you are interested in the requirement. Before responding please carefully read and consider the following: As this is a service acquisition, the Small Business Administration and the Federal Acquisition Regulation have a Limitations on Subcontracting requirement. For all small businesses, to include SDVOSB and VOSB, it will not pay more than 50 percent of the amount paid by the Government for contract performance to subcontractors that are not similarly situated entities.
Any work that a similarly situated entity further subcontracts will count towards the prime contractor's 50 percent subcontract amount that cannot be exceeded. When a contract includes both services and supplies, the 50 percent limitation shall apply only to the service portion of the contract. See FAR 52.219-14 and FAR 52.219-27 available in full text at https://www.acquisition.gov/far/html/52_217_221.html Brief Description of Services The VA Palo Alto Health Care System (VAPAHCS) has a requirement for Dry-type fire suppression system maintenance and testing of Grease hoods, exhaust fans and chemical Hazmat Sheds.
The Government is seeking only qualified kitchen exhaust cleaning specialists who hold current certification through the International Kitchen Exhaust Cleaning Association (IKECA) or an equivalent recognized industry association. Vendors must provide documentation demonstrating compliance with applicable NFPA standards, including NFPA 72 and 96, and furnish all required qualifications, training records, and certifications for personnel performing kitchen exhaust and grease hood cleaning services.
General This is a non-personal services contract to provide Dry-Type Fire Suppression System services for the VA Palo Alto Health Care System (VAPAHCS). The Government shall not exercise any supervision or control over the contract service providers performing the services herein. Such contract service providers shall be accountable solely to the Contractor who, in turn is responsible to the Government. Place of Performance: Palo Alto Main Campus 3801 Miranda Ave. Palo Alto, CA 94304 Menlo Park Medical Center 795 Willow Rd. Menlo Park, CA 94025 Livermore Medical Center 4951 Arroyo Rd. Livermore, CA 94550 Contractor Qualifications: Contractor shall possess a California C-16 contractor license and be certified by the system manufacturer to service and repair Ansul and related Automatic Fire Control Systems, or provide documentation of equivalent system training.
Grease hood cleaning shall be performed by International Kitchen Exhaust Cleaning Association (IKECA)-certified or equivalent association Certified Exhaust Cleaning Specialists (CECS), or personnel who can document compliance with all applicable NFPA 72 and NFPA 96 grease hood cleaning qualification and certification requirements. The Government reserves the right to request and review such licenses, certifications, and supporting documentation at any time during the contract period.
Preventative Maintenance and Testing Contractor shall provide all tools, materials, equipment, labor, and transportation to perform annual and semi-annual cleaning and fire protection services/ certification of the following grease hoods, exhaust fans, and chemical storage sheds at three divisions of the Veterans Administration Palo Alto Health Care System (VAPAHCS). All cleaning shall be done in accordance with NFPA 96 latest edition. All fire protection service/inspections and certifications shall be performed per NFPA 17A, 96, 10 and 72 latest editions.
Capability Statement The Government requests that only firms seriously interested and truly capable should send their capability information to the Contracting Officer, Kulvinder Brar by email at: Kulvinder.brar@va.gov no later than 3:00 PM Pacific Time, November 30, 2026: (a)Â Business Size (Large/Small) (b)Â Business Socio-Economic Status (SDVOSB, WOSB, 8(a), HUBZone, etc.) (c) SAM record (www.sam.gov) (d) VIP record (SDVOSB/VOSB firms only) (https://www.vip.vetbiz.gov/) (e)Â DUNS number (f) Ability and experience in managing similar projects.
Include general information and technical background describing your firm's experience on contracts requiring similar efforts to meet the program objectives. (g) List of Projects (Government and Commercial) that are similar in scope and size. (h) Anticipated Teaming Arrangements (if any) (i) GSA Contract Number if applicable. (j) Copies of certificates/licenses as identified above under Contractor Qualifications Interested parties shall not submit more than 10 single-sided, type-written pages using 12-point font or larger.
Published literature may be any number of pages. The Government will use this information when determining its business type decision. Â Â Â Â *Failure to provide the information requested above (items (a) (j)) will be considered non-responsive and will not be considered a viable source. DISCLAIMER This Sources Sought notice is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this request that is marked proprietary will be handled accordingly.
The Government will not compensate an offeror for providing information in response to this sources sought. Furthermore, the Government reserves the right to cancel this requirement at its discretion. This is simply a sources sought notice. Â Â Â Â
As published on SAM.gov.
Contacts
- Kulvinder Brar, Contracting Officer, Kulvinder.Brar@va.gov, 559-225-6100x 4273
As listed in the notice. Ask questions in writing and before the questions deadline, if the notice sets one.
History
- Nov 18, 2026: first seen in the SAM.gov extract
SAM.gov shows only the latest version of a notice. FedLook keeps a copy of each day's notices and records what changed.
Should you bid?
Nov 30, 3:00 PM PT5 days left
A free report for your company: whether you can bid, what to confirm first and who may hold the work now.
Get the free reportSimilar open notices
Open now under NAICS 811310, commercial and industrial machinery and equipment (except automotive and electronic) repair and maintenance, soonest deadline first.
- Department of Veterans AffairsHood, fire system and extinguisher service, Little Rock, AR
- US Coast GuardReplace crane turntable bolts at Cape May, NJ
- Department of the ArmyHalon fire bottle testing at Jacksonville Air Guard, FL
- Department of the NavyFlow meter verification at Pearl Harbor shipyard, HI
- Department of the Air ForceReplace gate valve frame at Flag Lake, Barksdale AFB, LA
- Department of the ArmyMaterial handling and industrial equipment repair
- Department of the Air ForceRepair of Sciaky spot welder at Tinker AFB, OK
- Department of the NavyFire extinguisher hydrostatic testing at Iwakuni, Japan
Free · at most one email a morning
Get new notices from Department of Veterans Affairs by email
Each morning we'll send the new solicitations and sources-sought notices from Department of Veterans Affairs, with deadlines and set-asides up front. Free. Unsubscribe in one click.
The morning edition by email: free, at most one email a morning, unsubscribe in one click. We use your address for nothing else and never share it. Privacy