UPS replacement and maintenance at Manchester VA, NH
The Manchester VA Medical Center wants a contractor to replace its end-of-life Eaton Powerware 80 kVA UPS with an Eaton UPS and extended battery cabinet, then provide preventive maintenance, standby and emergency labor, parts, and training for a base year plus four option years.
Official title: J061--Eaton Powerware System Replacement
- Deadline
- Nov 30, 5:00 PM ET
- 5 days left
- Who can bid
- SDVOSB firms
- Service-disabled veteran-owned small businesses certified by SBA only · Who qualifies
- Last time
- None found
- No contract like it at this agency in USAspending.gov
- Place
- Manchester, NH
- Buyer: 241-Network Contract Office 01 (36C241)
What they're buying
Only verified Service-Disabled Veteran-Owned Small Businesses may bid.
Top catches
“Submit quotations via email to Shawn.Lawrence@va.gov no later than November 26, 2026 at 5:00 PM EST.” 36C24127Q0030.docx
The base solicitation file says quotes are due November 26, 2026, which is tomorrow. The SAM.gov record and the later versions say November 30, 2026. Email the contract specialist today to confirm the date, and aim to submit by the earlier date.
“The concern will not pay more than 50% of the amount paid by the Government for contract performance, excluding the cost of materials, to subcontractors that are not similarly situated entities.” 36C24127Q0030.docx
You may not pay more than half of the government's payments to subcontractors that are not similarly situated. Sign and return the VAAR 852.219-75 certificate with your quote, or the government will not evaluate or award.
Read by AI (Claude Haiku) on Nov 25, 2026 from the notice and 4 of 12 attached files. Every quote on this page was found word for word in the source. Check the official notice before you bid.
The work
- Preventive maintenance and inspections of the UPS and batteries, 4 times a year (quarterly and annual), with a written monthly schedule to the COR.
- Standby labor for large electrical shutdowns, 48 hours a year, staffed within two weeks of notice.
- Emergency labor, 32 hours a year, with on-site response within 4 hours.
- Non-routine parts and materials, carried at a government not-to-exceed amount of $2,500 a year.
- Replace the existing 80 kVA Eaton Powerware UPS in kind with an Eaton UPS and extended battery cabinet, plus start-up, in the base year.
- Annual training on daily maintenance inspections, including a basic Eaton course.
Who did it before
No match in USAspending.gov: no contract at this agency for the same kind of work ends within a year either way.
What to watch for
- Due date conflicts across documents. The base solicitation file says quotes are due November 26, 2026, which is tomorrow. The SAM.gov record and the later versions say November 30, 2026. Email the contract specialist today to confirm the date, and aim to submit by the earlier date.
- Subcontracting cap for SDVOSB. You may not pay more than half of the government's payments to subcontractors that are not similarly situated. Sign and return the VAAR 852.219-75 certificate with your quote, or the government will not evaluate or award.
- Eaton-certified technicians required. The VA says PM technicians must be factory-certified or Eaton-authorized, except for minor work such as filter changes. If your staff are not Eaton-certified, you must subcontract that work, and it counts toward the 50% cap.“Due to the complex nature of the product and criticality - Yes” 36C24127Q0030_3.docx
- Replacement size conflicts: 60 or 80 kVA. The SOW specifies a 60 kVA replacement, but the Q&A says the existing unit is 80 kVA and should be replaced in kind. Ask the contract specialist to confirm the rating before you price the UPS.“Existing UPS is 80KVA. The goal is to replace-in- kind. The 60kVA was utilized as a basis of design.” 36C24127Q0030_3.docx
- Labor rates set by unread wage file. The Service Contract Labor Standards apply, so the wage determination sets your labor costs. We could not read that attachment, so you must read it before you price the labor lines.“This is a recurring service contract exceeding $2,500 performed in the United States; the Service Contract Labor Standards (SCLS/SCA) apply.” 36C24127Q0030.docx
- Parts limit conflicts with SOW. The price sheet sets parts at $2,500 a year not-to-exceed, but the SOW allows $500 per item per visit. Price the line at $2,500 as the note directs, and ask which limit governs.“The Contractor shall supply parts and materials ($500 per equipment item per visit) as needed for upgrades, replacement, and repairs.” 36C24127Q0030.docx
Key terms
| Who can bid | Service-Disabled Veteran-Owned Small Businesses onlySize standard for NAICS 811310 is $12.5 million, per the notice. You must be a verified SDVOSB.36C24127Q0030.docx |
|---|---|
| Contract period | Base year January 4, 2027 to January 3, 2028, plus four 12-month option yearsOption years are exercised only if the government chooses to exercise them.36C24127Q0030.docx |
| How they choose | Most advantageous to the government, price and other factors consideredPrice is the total of all line items, including option years. The relative weight of other factors is not stated.36C24127Q0030.docx |
| How to submit | Email to Shawn.Lawrence@va.govThe signed VAAR 852.219-75 certificate must be returned with the quote. |
| Questions due | November 19, 2026, 5:00 PM EST (passed)Questions were due by email to the contract specialist. This date has passed. |
| Contract type | Commercial services, request for quotation (RFQ)Quotes are requested. No written solicitation document will be issued.36C24127Q0030.docx |
| Site visit | Monday, November 16, 2026, 9:00 AM EST (passed)Attendance was optional. The notice of intent to attend was due November 12, 2026. Both dates have passed.36C24127Q0030.docx |
How to respond
- Before November 26, 2026, email Shawn.Lawrence@va.gov to confirm the due date, since the documents disagree.
- Send your quote by email to Shawn.Lawrence@va.gov by the confirmed time, 5:00 PM EST. File format and size limit: Not stated.
- Include the solicitation number, your company name, address, phone and UEI, and your statement on the contract terms in 52.212-4. Include the signed VAAR 852.219-75 certificate.
- Include qualification and certification details for your staff and any subcontractors, including the Eaton-authorized partner.
- Fill in unit and extended prices for the base year and option years 1 to 4. Carry the $2,500 parts line as shown, and hold your prices for 60 calendar days.
Attached files
From SAM.gov. Download links open the original files.
- 36C24127Q0030_3.docxThe version that appears to be the latest, with the questions and answers about the UPS. Read it in full. No form to sign. Read.
- 36C24127Q0030_2.docxA version dated November 30, 2026 with an updated site-visit contact. Read it only. No form to sign. Read.
- UPS Installation Instructions.pdf Scanned image, not read.
- Attachment B - Wage Determination No 2015-4019 rev 35.pdf Scanned image, not read.
- UPS Eaton 9390 product info.pdf Scanned image, not read.
- UPS Drawings and Other Info.pdf Scanned image, not read.
- UPS Manual Section II Operation.pdf Scanned image, not read.
- https://sam.gov/api/prod/opps/v3/opportunities/resources/files/733b580bf339484fa0b627582432dead/download Could not be read.
- 36C24127Q0030_1.docxAn earlier version of the notice header, also dated November 26, 2026. Read it only for comparison. Read.
- Attachment A - Eaton 93E UPS manufacturer cut sheets and site electrical drawings Start-Up.pdf Scanned image, not read.
- 36C24127Q0030.docxMain solicitation with the statement of work, price sheet, clauses and subcontracting certificate. You must fill in prices, sign the certificate and return it. This version gives a November 26 due date. Read.
- UPS Guide Specification.pdf Scanned image, not read.
Not stated in what we read
- Estimated value of the contract: Not stated, and the price lines are blank.
- Relative weight of the evaluation factors: the clause refers to a Section 7 that is not in the text.
- Whether a maintenance bypass sidecar must be supplied with the UPS. The Q&A does not say.
- Whether start-up is priced separately. The start-up scope is in Attachment A, which we could not read.
- Personnel vetting requirements: Attachment D is referenced but was not provided.
- Several scanned files were not readable, including the wage determination, Attachment A, manuals, drawings and the UPS guide specification. You must read them yourself before pricing.
Notice text
36C24127Q0030 UPS Eaton Powerware System Replacement - RFIs Does the VA require technicians performing quarterly and annual preventive maintenance to be individually factory-certified or authorized by Eaton? Due to the complex nature of the product and criticality - Yes Will documented experience and technical qualifications satisfy the qualification requirement for routine preventive maintenance? See answer to RFI 1 Is direct access to Eaton's proprietary field-service software mandatory for the prime contractor, or may that requirement be fulfilled through an Eaton-authorized service provider supporting specific procedures?
Prime Contractor does not require that; That portion can be filled through an Eaton Authorized Technician. Would a contractor be considered technically acceptable if it performs routine maintenance using qualified technicians and subcontracts manufacturer-restricted procedures and startup to Eaton? Yes, minor PM work such as filter changes etc. would be outside the requirement of needing an Eaton Technician. Since Eaton has discontinued the 93E product line, will the VA accept the current Eaton 93PM or another equivalent replacement system meeting the required performance specifications?
The VA would accept an Eaton alternative. The goal of the project is to replace existing equipment in-kind with newer model. Does the existing Eaton Powerware 9390 system have an external maintenance bypass (for example, a maintenance bypass panel or a bypass sidecar with maintenance bypass and isolation breakers)? Yes, See photos. Is the replacement expected to include a maintenance bypass sidecar, such as the Eaton 93E 60 kVA bypass sidecar shown in Attachment A, or is it limited to the UPS and Extended Battery Cabinet listed in SOW Section 3.5?
The UPS is required to be able to go into maintenance Bypass and maintain power to the computer room during maintenance. What is the kVA rating of the existing unit? The SOW says "Model 80," but the replacement is specified at 60 kVA. Existing UPS is 80KVA. The goal is to replace-in- kind. The 60kVA was utilized as a basis of design. What are the existing input voltage and output voltage? Current system: Eaton Powerware 9390-80 Model 80 AC IN: 208VAC 3W 60Hz 3Phase 240A AC OUT: 208VAC 4W 60Hz 3Phase 222A 78KW 80KVA BYPASS: 208VAC 4W 60Hz 3Phase 222A 80KVA DC: 384-480Vdc 204A Please provide a photo of the existing unit's data plate.
See attached photos Please provide photos of the full system (standing back) and of the battery cabinet and batteries. See attached photos Please confirm the battery quantity and model: 40 x Hitachi Chemical Energy Technology 12V 540W, HRC12540WP. Confirmed What is the current battery run time, and what run time is required for the replacement? 60 minutes would it be possible to forward the latest performance specifications/Source Control Drawings for the Powerware System attached Will the VA be paying invoices on a Net-30/45/60 schedule? The VA approves all invoices within 15 days and funds are transferred within 30 days of receipt.
As published on SAM.gov.
Contacts
- Shawn Lawrence, Contract Specialist, Shawn.Lawrence@va.gov, 914-737-4400 ext. 202121
As listed in the notice. Ask questions in writing and before the questions deadline, if the notice sets one.
History
- Nov 25, 2026: first seen in the SAM.gov extract
SAM.gov shows only the latest version of a notice. FedLook keeps a copy of each day's notices and records what changed.
Should you bid?
Nov 30, 5:00 PM ET5 days left
A free report for your company: whether you can bid, what to confirm first and who may hold the work now.
Get the free reportSimilar open notices
Open now under NAICS 811310, commercial and industrial machinery and equipment (except automotive and electronic) repair and maintenance, soonest deadline first.
- Department of Veterans AffairsHood, fire system and extinguisher service, Little Rock, AR
- US Coast GuardReplace crane turntable bolts at Cape May, NJ
- Department of the ArmyHalon fire bottle testing at Jacksonville Air Guard, FL
- Department of the NavyFlow meter verification at Pearl Harbor shipyard, HI
- Department of the Air ForceReplace gate valve frame at Flag Lake, Barksdale AFB, LA
- Department of the ArmyMaterial handling and industrial equipment repair
- Department of the Air ForceRepair of Sciaky spot welder at Tinker AFB, OK
- Department of the NavyFire extinguisher hydrostatic testing at Iwakuni, Japan
Free · at most one email a morning
Get new notices from Department of Veterans Affairs by email
Each morning we'll send the new solicitations and sources-sought notices from Department of Veterans Affairs, with deadlines and set-asides up front. Free. Unsubscribe in one click.
The morning edition by email: free, at most one email a morning, unsubscribe in one click. We use your address for nothing else and never share it. Privacy